The second part of the midas Gen pushover series defines what pushover analysis is and then compares the four established methods for seismic performance evaluation built on it. The displacement coefficient method, capacity spectrum method, modal pushover analysis and direct displacement based design are each described with their characteristics, procedures and known limitations. The comparison is intended to help the engineer choose a method appropriate to the structure and to the design stage.
Key Topics
What Pushover Analysis Is
Pushover analysis is a static procedure using a simplified nonlinear technique to estimate seismic deformations. It reflects the fact that structures redesign themselves during an earthquake, since as components yield or fail the dynamic forces shift to other components; loads are applied until the weak link appears, the model is revised, and the process repeats until the yield pattern of the whole structure is identified. It is used mainly to evaluate the seismic capacity of existing structures, and appears in retrofit guidelines, but it also serves performance-based design of new buildings that rely on ductility or redundancy.
The Four Evaluation Methods and Their Sources
The methods surveyed are direct displacement based design from the SEAOC Blue Book, the capacity spectrum method from ATC-40, the displacement coefficient method from FEMA-273, and modal pushover analysis from the work of Chopra and Goel. Each traces to a specific guideline or research paper, which matters because the acceptance criteria travel with the method. Grouping them this way shows that the choice is a choice of framework, not just of formula.
Displacement Coefficient Method
The target displacement is obtained by multiplying the maximum displacement of the elastic system by a dynamic coefficient that is a statistical empirical value derived from single degree of freedom response. Initial stiffness dominates the result while the effect of strength is ignored, making the method simple and practical and therefore suited to preliminary design. Its known weaknesses are that the primary coefficient is biased in opposite directions above and below a characteristic period, that the hysteresis and P-Delta coefficients lack reliability, and that it should be avoided on soft ground.
Capacity Spectrum Method
The capacity spectrum method reduces stiffness through a secant stiffness, accounts for hysteretic energy dissipation as equivalent viscous damping, and uses an equivalent linearization technique so that stiffness and strength effects at maximum displacement are expressed effectively. The performance point is found where the capacity spectrum intersects the demand spectrum in spectral acceleration versus spectral displacement coordinates. It is the most widely applied method for seismic performance evaluation of existing buildings, but it is valid only when behavior is governed by one dominant mode and gives unreliable results for weak-story buildings or where higher modes matter.
Refinements of the Capacity Spectrum Method
Because of these limitations, variants such as the corrected capacity spectrum method and the direct capacity spectrum method have been researched. The displacement coefficient method is itself described as the design-side complement to the capacity spectrum method, being displacement based and using a limit displacement that reflects the inelastic failure mechanism. The note directs the reader to part three of the series for the full capacity spectrum procedure.
Modal Pushover Analysis
Modal pushover analysis keeps the simple concept and convenient computation of a pushover procedure while securing accuracy, because it reflects the characteristics of each mode and so accounts effectively for higher modes. Its steps are to form uncoupled modal equations, compute a target displacement for each mode, convert each to an inelastic single degree of freedom system, analyse that system dynamically, convert back to a modal performance point of the multi degree of freedom system, obtain the response there, and finally combine the modal responses by square root of sum of squares. The modal force distribution and the idealisation of each mode's pushover curve, including yield displacement and strain hardening ratio, are defined from the elastic frequencies and mode shapes.
Direct Displacement Based Design
Direct displacement based design starts from a selected target displacement, converts the structure to an equivalent single degree of freedom system with an effective mass and design displacement, and computes an effective stiffness and trial effective period. Damping is then calculated from the ductility implied by the ratio of design to yield displacement, and the effective period is recomputed and iterated until it matches the trial value. Once converged, the design base shear follows directly as the effective stiffness times the design displacement.
Choosing Among the Methods
The comparison implies a practical division of labour: the displacement coefficient method for preliminary sizing because of its simplicity, the capacity spectrum method for evaluating existing buildings dominated by a single mode, modal pushover analysis where higher modes or weak stories make a single-mode assumption unsafe, and direct displacement based design where the design is driven from a displacement target. Each method's stated limitations are the criteria for exclusion. This makes method selection an explicit engineering decision.
Pushover analysis identifies the successive weak links and the eventual yield pattern of a structure through a simplified nonlinear static procedure, and four established frameworks convert that capacity curve into a performance assessment. The displacement coefficient method is simplest but biased, the capacity spectrum method is the most widely used for existing buildings yet assumes single-mode dominance, modal pushover analysis restores higher-mode accuracy at modest cost, and direct displacement based design works backwards from a displacement target to a design base shear.