This technical note distinguishes two rotation quantities reported by midas Gen after a pushover analysis: element rotation, which is a chord rotation derived from lateral displacement, and hinge rotation, which is derived from the bending moment and the hinge stiffness. It shows how each is computed, works both through on a two-element column model at a chosen pushover step, and identifies which code provisions call for which quantity. The distinction matters because the two values can differ substantially for the same member.
Key Topics
Definition of Element Rotation
Element rotation is the angle caused by the lateral deformation of the element itself, obtained as the total chord rotation, that is the relative lateral displacement divided by the member length, minus the rotation contributed by the deformation of the adjacent restraining members. Removing the nodal rotation is what isolates the deformation belonging to the element from the rigid-body rotation imposed by its neighbours. The note derives it separately at each end of a member, since the nodal rotation differs at the two ends.
Definition of Hinge Rotation
Hinge rotation is the rotation of the member at a specific location caused by the bending moment there, computed from the moment divided by the flexural stiffness of the hinge rather than from displacements. Because it is a moment-based quantity, a location with zero moment has zero hinge rotation even where the chord rotation is large. A cantilever comparison shows the two definitions giving markedly different values at both the fixed and the free end.
Worked Element Rotation Calculation
For a two-element column of a given height at the fiftieth pushover step, the lateral displacements and nodal rotations at each node are tabulated, and the element rotation at each element end is formed as the displacement difference divided by the length minus the nodal rotation at that end. The four resulting values differ from one another because both the displacement increment and the nodal rotation vary along the column. The note adds that the midas Gen output differs slightly because the program also removes the rotation attributable to shear deformation.
Worked Hinge Rotation Calculation
Hinge properties are defined by an initial stiffness, a yield moment and a yield rotation, with post-yield stiffness set to one tenth of the initial value. The elastic part of the hinge rotation is the lesser of the acting and yield moment divided by the initial stiffness, the plastic part is the excess of the acting moment over the yield moment divided by the post-yield stiffness, and the total is their sum. Locations where the moment has not reached yield therefore report only an elastic rotation with no plastic component.
Where Element Rotation Is Used
Element rotation is the quantity required by the safety verification of Eurocode 8 Part 3, and it also serves as a drift measure for models that have no story definition. In midas Gen the check is run from the pushover hinge result safety verification, where the demanded element rotation is compared against a capacity element rotation and each hinge is reported as acceptable or not. FEMA 356 likewise refers to this quantity in its commentary on acceptance measures.
Where Hinge Rotation Is Used
Hinge rotation is the quantity compared against the acceptance criteria of FEMA 356, where the analysis result for each hinge is checked against the tabulated performance limits. Using the chord-based element rotation in place of the moment-based hinge rotation, or the reverse, would misstate the acceptance check, which is why the note works both quantities through on the same model and step.
Element rotation is a displacement-based chord rotation with the neighbouring members' rotation removed, whereas hinge rotation is derived from the acting moment and the elastic and post-yield hinge stiffness, and the two can differ greatly at the same location. Eurocode 8 Part 3 safety verification is based on element rotation while FEMA 356 acceptance criteria are based on hinge rotation, so the correct quantity must be read from the pushover results for each check.