This note defines the center of stiffness within a floor-diaphragm plan and presents an approximate method, with a worked example in midas Gen, for locating it so that design eccentricity can be evaluated.
Key Topics
What the Center of Stiffness Is
It is the stiffness centroid of a floor diaphragm; a lateral load acting through it causes only translation of that diaphragm. It depends on structural properties, not on the loading, and some building codes require it for multistory design-eccentricity provisions.
Calculation Method
For each lateral-load-resisting element (columns, shear walls, bracings), the lateral stiffness K is taken as story shear divided by story drift, with coordinates X and Y. The center of stiffness coordinates are the stiffness-weighted averages, lX = sum(K*X)/sum(K) and lY = sum(K*Y)/sum(K).
Worked Example
For a four-story, two-way symmetric model with equal columns, the Y-direction center of stiffness at the third floor is found in three steps: obtain the column shears at the second floor, obtain the story drift between the second and third floors, then compute each element stiffness and the stiffness-weighted coordinate.
Accuracy Caution
The method is approximate and is not an official code method. In the symmetric example it returned 3.42 m where the exact value is 3.5 m, so the result should be used only as a reference.
The center of stiffness can be estimated from the story shear and story drift of each lateral-load-resisting element as a stiffness-weighted average of their coordinates, but the value is approximate and should be treated as a reference rather than an exact result.