[EN_GEN] High-rise building design_S02 Introduction of Structure System & How to do the case study

PDF
·
17 pages
·
3.2MB
·
English
·
Updated 2025.03.11
Summary

This second instalment of the high-rise design series introduces the main lateral resisting systems used in tall buildings and shows the case study method by which one is selected. Outrigger and belt truss, spine wall and fin wall, diagrid and mega column and brace systems are each explained conceptually and then examined through a worked project comparison. The distinctive contribution is a quantitative procedure for measuring how much stiffness each system element contributes and how much material it costs.

Key Topics

01

Systems by Building Height

Lateral resisting systems are mapped against the number of stories separately for steel and for concrete buildings, running from outrigger and belt truss arrangements through tube systems, core plus tube, core plus spine wall and mega structures. The chart establishes which systems are candidates at a given height before any analysis begins.

02

The Outrigger and Belt Truss Concept

A core acting as a pure cantilever carries all the overturning moment itself, whereas an outrigger connected to the perimeter columns converts part of that moment into a couple carried by axial force in those columns, with a belt truss distributing the force around the perimeter. The presentation states that the arrangement improves structural efficiency by roughly thirty percent. Empirical optimum positions are given as a single outrigger placed a little below mid-height and, for two outriggers, at about one third and two thirds of the height.

03

Measuring Stiffness Contribution by Element

The efficiency of an outrigger system is analysed by building the model up in four steps, starting from the core alone with pinned super columns, then adding the outrigger and belt truss, then making the super columns a moment frame, then adding the exterior wall. A representative displacement is defined as the root mean square of the story displacements and a representative stiffness index as its reciprocal, so the increment of stiffness between successive steps gives each element's relative stiffness and its percentage participation. In the worked example the outrigger and belt truss provide roughly half of the total stiffness, far more than the core alone, which identifies where to invest material and what can be reduced.

04

Spine Wall and Fin Wall Systems

A spine wall system resists lateral force with walls arranged along the internal circulation of the building, and needs attention to torsion, which can be resolved by forming the core as a closed box or triangular shape. A fin wall crosses the plan on one or both sides of the core and, for structural efficiency, is usually carried only up to a middle story. The Burj Khalifa and other towers are cited as examples, and the main disadvantage noted is the constraint the walls place on the architectural plan.

05

Case Studies of Spine and Fin Wall Alternatives

A comparison of a core plus outrigger scheme against a core plus fin wall scheme on the same tower shows the fin wall alternative reducing wind drift by around a quarter. Connecting an isolated spine wall raises stiffness by more than the quantity it adds, so the efficiency measured as stiffness per unit quantity improves, and placing a fin wall at the end of a spine wall is identified as particularly effective. A twelve-step alternative study tracks efficiency across successive additions of spine wall, core wall, lintel beam, doubled spine wall, fin wall and belt wall, and a separate table shows a development sequence that removed inefficient walls and then added spine and fin walls, cutting concrete volume, reinforcement weight and formwork area by significant margins relative to the architect's initial plan.

06

Diagrid Systems

A diagrid places inclined members on the building exterior as a diamond grid truss that carries both gravity and lateral load. Closed-form expressions are given for the diagonal member forces arising from vertical load, from the overturning moment and from the shear component, all as functions of the grid angle. Referring to published work on the preliminary design of diagrid tall buildings, the study of a sixty-story diagrid with corner columns finds that grid angles in the range of roughly fifty to seventy degrees minimise the horizontal displacement.

07

Mega Column and Brace Systems

A mega structure resists very large lateral and vertical loads using columns and trusses of enormous size, combining several arrangements according to the character of the lateral load, and takes the form of overlapping modular members or a complex three-dimensional truss. The structural system and load path of a reference tower are shown for both gravity and lateral force. A brace module case study on that tower found the brace angle most effective in a band of roughly thirty-five to seventy degrees, which then fixed the module height.

Conclusion

Selecting a lateral system for a tall building is a comparative exercise, not a catalogue choice: outrigger and belt truss, spine and fin wall, diagrid and mega braced frame systems each suit particular heights and plans, and each depends strongly on geometric parameters such as outrigger elevation or brace angle. Building the model up element by element and measuring the representative stiffness increment against the added quantity identifies which elements to strengthen and which to remove, and the case studies show substantial material savings from that process.

Related Resources

Hand-picked materials in the same category and topic to deepen your workflow.

STRUCTURE · EXPERT COLUMN[KR_김종수,2015] 02_초고층 건물의 횡력시스템_골조공사비_공기 사례
STRUCTURE · SEMINAR[KR_2008.08] Part.1 Diagrid System 초고층건물 구조시스템의 최신동향과 적용사례
STRUCTURE · MIDAS NOTE[EN_GEN] High-rise building design_S07 Field Engineering in High-rise building
STRUCTURE · SEMINAR[KR_2008.00] Structural System of NorthEast Asia Trade Tower(하인호)