This note derives ASCE 7-16 wind pressures for a building with a single-slope roof and shows how to apply them in a midas Gen model. It follows the velocity pressure calculation factor by factor, selects the external pressure coefficients for the walls and the monoslope roof, tabulates the net pressures for the positive and negative internal pressure cases in each wind direction, and closes with the load case creation, floor load input and load combination steps in the program.
主要内容
Example Model Definition
The building has a mean roof height of about eight and a half metres, a long rectangular plan with the long dimension roughly two and a half times the short one, and a roof pitched at about twelve degrees in one direction only. It is assigned a basic wind speed of thirty metres per second, risk category two with unit importance factor, and exposure category C. The strongly rectangular plan means the wall pressure coefficients differ substantially between the two wind directions.
Velocity Pressure Factors
Velocity pressure is formed from the standard coefficient times the velocity pressure exposure coefficient, the topographic factor, the wind directionality factor, the ground elevation factor and the square of the basic wind speed. The ground elevation factor is unity and the directionality factor takes the standard building value. The exposure coefficient is interpolated from the code table for exposure category C at the mean roof height.
Topographic Factor and Pressure Distribution
The topographic factor is built from three coefficients set by the hill type, the height-to-length ratio, the distance from the crest and the height above ground, evaluated here for an assumed two-dimensional escarpment with interpolation on the height ratio. Combining the height-varying exposure and topographic factors gives a velocity pressure tabulated level by level, whose maximum occurs at the mean roof height. That single maximum value is used throughout, with the note observing that level-specific values could be applied instead.
Two Internal Pressure Cases
The net pressure on each surface is the external pressure minus the internal pressure, and because the internal pressure coefficient may be positive or negative there are two values per surface. The note carries both cases through, illustrating on a section which faces receive positive and which negative internal pressure. Since the governing surface changes between cases, both must be included in the model.
Surface Pressure Coefficients
With the gust effect factor at the standard assumed value, and noting that it may instead be computed from the relevant clause, coefficients are taken for the windward wall, the leeward wall and the side walls from the plan aspect ratio, and for the monoslope roof from its pitch and the height-to-plan ratio. Each surface pressure is the velocity pressure times the gust factor times the coefficient, evaluated for wind along each plan direction. Because the roof slopes one way only, there is a windward roof value but no separate leeward roof slope in one of the directions.
Summary of Net Pressures
A summary table lists the net pressure on the windward, leeward and side walls and on the roof for wind along each plan direction, in each internal pressure case, with a positive sign denoting pressure toward the inside of the building and a negative sign pressure acting outward. In the positive internal pressure case most surfaces carry outward suction with only a small inward pressure on the windward wall, whereas in the negative internal pressure case the windward wall pressure is much larger and the suctions are greatly reduced. The contrast confirms that neither case can be dropped.
Entering the Loads in midas Gen
Load cases are created for the full matrix of the two internal pressure cases, the two plan wind directions and the two pressure signs, each with separate windward, leeward and side entries. The tabulated pressures are then entered as floor loads on the corresponding surfaces, with the sign corrected according to the actual direction of action on that face and a mirrored floor load type created for the opposite direction. Load combinations including these wind cases are generated as the final step.
ASCE 7-16 wind loading on a monoslope roof building is derived by building the velocity pressure from the exposure, topographic, directionality and elevation factors, then applying wall and roof pressure coefficients for wind in each plan direction under both positive and negative internal pressure. The two internal pressure cases produce very different distributions, so both are entered in midas Gen as floor loads across a systematic set of load cases before combinations are generated.