This note reviews the approximate method for locating the center of stiffness that is documented in the online manual, points out that it is neither a code method nor clearly accurate, and proposes an iterative alternative that converges on the true center. The approximate method is worked through on a small symmetric example, and the discrepancy in the result motivates the proposal. The alternative uses repeated analyses in which the applied nodal load is moved to the computed center until the two coincide.
主要内容
The Approximate Manual Method
Each lateral load resisting element is assigned a lateral stiffness taken as its story shear divided by the story drift, and the center of stiffness coordinates are computed as the stiffness-weighted average of the element coordinates in each direction. The note records that this approach originated with a Japanese engineering practice and is widely used there, but that it is not based on any code provision. It requires only the beam force table and the story drift table from an ordinary lateral load analysis.
Worked Example and Its Discrepancy
The method is applied to a small regular frame to find the center of stiffness in one direction at an upper floor, building a table of element stiffness from column shears and the story drift, then forming the stiffness-weighted coordinate. For this plan the result falls slightly away from the position that symmetry would suggest. The note flags this as evidence that the method is not clear enough to be relied on and asks how the accurate center can be obtained.
Proposed Iterative Procedure
The alternative exploits the defining property of the center of stiffness, namely that a lateral load acting through it produces pure translation. A nodal load is applied at an arbitrary position and the analysis is run, the center of stiffness reported in the result table is read, and the load is then moved to those coordinates and the analysis repeated. The iteration continues until the position of the applied load and the computed center coincide, at which point the exact center has been found.
Convergence and Tolerance
The note illustrates four successive steps of the iteration, showing the load position and the computed center approaching one another. Convergence is judged by the user, who must decide what difference between the two positions is acceptable. The procedure is presented for midas Gen and is equally applicable in midas Civil.
The stiffness-weighted average of element stiffnesses derived from story shear and drift is a convenient but unofficial and imprecise way to locate the center of stiffness. Applying a nodal load and iteratively relocating it to the computed center until the two positions agree converges on the true center of stiffness, with the acceptable tolerance left to the engineer.