概要

This technical note explains what imperfection loads are, why the Eurocodes require them, and how to generate them in midas Gen and midas nGen. It distinguishes global sway imperfection from local bow imperfection and shows how each is accounted for, the first as equivalent horizontal loads in the analysis model and the second as an additional moment at the design stage. Manual and program-based examples are worked through, followed by tutorials for both programs and notes on practical application.

主要内容

01

Two Categories of Geometric Imperfection

Columns and walls are never perfectly straight or perfectly plumb as built, and this geometric imperfection threatens the stability of the compression member. A verticality error produces a global, or initial sway, imperfection whose effect is an additional moment equal to the sum of the vertical loads times the sway displacement. A straightness or flatness error produces a local, or initial bow, imperfection whose effect is an additional moment equal to the axial force times the bow eccentricity in the individual member.

02

How Each Type Is Treated

Local imperfection is generally not modelled in the analysis but is handled in design, by adding the moment generated by a bow eccentricity taken as a fraction of the member length to the moment from the first-order analysis. Global imperfection is instead built into the analysis model, realised as lateral loads formed by multiplying the axial force in each vertical member by the imperfection angle. Consequently the sway effects appear directly in the analysis results while the bow effects appear only in the member design.

03

Equivalent Horizontal Loads and When They Can Be Omitted

The global initial sway imperfection is expressed as a coefficient multiplied by the total design vertical load of the structure, giving an equivalent horizontal load. The coefficient is built from a basic value together with reduction factors for the height of the structure and for the number of columns in a row. Eurocode 3 permits the notional horizontal load to be ignored where the actual applied lateral load exceeds a modest fraction of the vertical load in the member, and the note gives that criterion explicitly.

04

Converting Imperfection Forces to Nodal Loads

The imperfection force at each level is the story axial force times that level's coefficient, but the loads actually entered at the nodes are the differences between successive levels, so that the resultant at each floor is correct. A worked five-story example tabulates the axial force and coefficient at each level, the resulting imperfection force, and the differenced nodal load applied at that floor. A second example computes the coefficient itself from the story height and the number of columns for two individual columns and derives the top and bottom nodal loads.

05

Tutorial in midas Gen

The coefficient is calculated under the imperfection data command in the settlement and miscellaneous load menu, where the number of columns in a row is entered and an option allows a user-defined coefficient instead. The create imperfection load command then automatically generates the load case and the nodal loads: the user names the imperfection, selects the target gravity load case that supplies the vertical force and the direction, and confirms which imperfection load cases to create, each named from the imperfection name and the source static load case. Load combinations are then generated, and a result table for imperfection shows how the factored loads are applied and whether the lateral load in each combination is small enough that the imperfection load remains required.

06

Tutorial in midas nGen

In nGen the initial sway coefficient is defined under the lateral load imperfection menu, with automatic calculation from the story height and number of columns as well as a user-defined option. Columns lying on the same line for a given axis angle are counted automatically and the maximum number of columns is reported in the imperfection data table, with separate entries for the major and orthogonal directions. Assigning the imperfection then creates the load case and nodal loads, named from the imperfection name, the source static load case and the direction.

07

Limitations in nGen

The equivalent load for local imperfection is not supported, so for walls the nodal load must be defined by the user. The imperfection load is defined against the summed axial force of the story, and the analysis distributes it to the nodes in proportion to their mass ratios. The note also observes that small differences between hand-calculated and program values arise from rounding rather than from a difference in method.

まとめ

Eurocode stability design requires both a global sway imperfection, applied as equivalent horizontal loads proportional to the vertical load through a height and column-count dependent coefficient, and a local bow imperfection, added as a member moment at the design stage. midas Gen and nGen both compute the coefficient and generate the imperfection load case and differenced nodal loads automatically, with a result table confirming whether the notional load is still required for each combination.