This technical note explains how midas nGen selects the positions along a beam at which member forces are taken for design, and how the user can control them. By default the member is divided into four parts giving five check positions, which introduces a small conservative error relative to the true peak moment. The note describes when that error becomes significant and how to reduce it by adding check positions.
主要内容
Default Five Design Positions
The program sets specific design positions along the member and designs using the member forces at those positions. In general the member is divided into four parts, giving check positions at the two ends, the quarter points and midspan. The design moment at the middle part therefore differs slightly from the true peak moment, but the difference is on the safe side once design overstrength is considered.
Automatically Added Positions
When a point is created on the beam, the member force at that point is automatically reflected in the design regardless of the user's check-position setting. Such points include the location where a concentrated load from a supported beam is applied, both ends of the range over which a beam load acts, and any position carrying a concentrated load. This ensures that discontinuities in the force diagram are always captured.
When the Default Positions Are Insufficient
If a local force occurs, or if the negative moments at the two ends differ substantially because of unequal end restraint stiffness, the peak member force migrates away from midspan. In that situation the value taken at a fixed check position can differ noticeably from the actual peak. The note illustrates a case where the design moment initially falls well below the peak moment.
Reducing Error by Adding Check Points
The error is reduced simply by increasing the number of design positions along the member. Adding intermediate positions between the quarter points and midspan brings the design moment essentially into agreement with the peak moment. This gives the engineer direct control over the conservatism of the extracted design forces.
Practical Workflow
The feature is accessed through the Check Position command in the Design tab. The user selects the member type, picks the target members in the modeling window, enters the desired number of check points, and confirms. This applies the revised design positions to the selected members only.
The note shows that midas nGen designs beams from member forces sampled at discrete check positions, five by default, supplemented automatically at load discontinuities. Where unequal end stiffness or local loading shifts the peak force away from these sampling points, increasing the number of check positions through the Check Position command brings the design force back into line with the actual peak.