This material presents the design procedures for reinforced concrete and steel members according to EN 1992-1-1:2004 and EN 1993-1-1:2005 as a series of flow charts. Each chart begins from the design forces obtained by elastic analysis and leads step by step to the required reinforcement or the section verification, with the supporting code tables reproduced alongside. It is a companion to the separate Eurocode 2 and Eurocode 3 design guides for midas Gen, which cover the program implementation in detail.
主要内容
Flexural Design of Concrete Beams
The chart determines the normalised moment parameter from the design moment and the section geometry and concrete strength, compares it with a limiting value derived from the moment redistribution ratio, and branches according to whether compression reinforcement is needed. In the singly reinforced branch the lever arm is computed from the moment parameter with a cap, and the tension steel follows from the moment divided by the design steel stress and lever arm. Both branches finish with checks on the minimum reinforcement, which depends on the mean tensile strength of the concrete, and on the maximum reinforcement expressed as a fraction of the gross concrete area.
Shear Design of Concrete Beams
The design shear stress is formed from the shear force divided by the web width and the lever arm, then compared with the concrete strut capacity evaluated at the shallowest permitted strut angle. If the demand is below that capacity the shear reinforcement is sized directly with the shallow strut angle; if it lies between the shallow and steep limits the strut angle is solved from the demand before sizing the links; and if it exceeds the steep limit the section must be redesigned. A table of minimum and maximum strut capacities against concrete grade supports the branching, and the maximum link spacing is checked as a fraction of the effective depth.
Braced Concrete Column Design
Starting from the design axial force and the end moments, the chart establishes the effective length from the standard restraint cases, forms the two first-order end moments including the imperfection eccentricity taken as the largest of a length-based term, a depth-based term and a minimum value, and computes the slenderness from the effective length and radius of gyration. That slenderness is compared with a limit built from the creep, reinforcement and moment ratio factors and the relative axial force. A non-slender column is designed for the larger first-order end moment, with the reinforcement found by iteration and the spacing and quantity rules checked.
Slender Concrete Column Design
For a slender column the nominal curvature method is followed: a relative axial force factor and a creep factor are evaluated, from which the second-order deflection is computed as a function of the effective length. The design moment is then taken as the largest of the upper first-order end moment, the equivalent first-order moment plus the full second-order moment, and the lower end moment plus half the second-order moment. Because the axial force factor depends on the provided reinforcement, the process iterates until the required and provided areas agree, after which detailing requirements are checked.
Simply Supported Steel Beam Design
The steel chart assumes a grade and trial section, classifies the cross section, then evaluates the moment resistance from the plastic modulus for Class 1 and 2 sections or the minimum elastic modulus for Class 3 sections and verifies it against the design moment. Shear resistance is evaluated from the shear area, web shear buckling is checked when the web slenderness exceeds the code trigger, and when the shear demand exceeds half the plastic shear resistance the moment resistance is reduced for the shear interaction. Comprehensive tables of maximum width-to-thickness ratios are reproduced for internal compression parts, outstand flanges, angles and tubular sections, along with the strength-dependent epsilon factor.
Lateral-Torsional Buckling Check
The lateral-torsional buckling branch computes the non-dimensional slenderness from the section modulus, yield strength and elastic critical moment, and skips the check when that slenderness is small. Otherwise the reduction factor is obtained from the standard buckling curve expression using an imperfection factor selected by the buckling curve, which in turn is chosen from whether the section is rolled or welded and from its depth-to-width ratio. The buckling resistance moment is then compared with the design moment, and a new section is trialled if it fails.
Steel Tension Member Design
For a member in tension the chart sizes a trial section from the design axial force and yield strength, then determines the design tension resistance as the lesser of the gross section plastic resistance and the net section ultimate resistance, the latter reduced by a factor and computed with the partial factor for ultimate resistance. The design force is then verified against that resistance.
The document condenses Eurocode 2 and Eurocode 3 member design into flow charts covering concrete beam flexure and shear, braced and slender concrete columns, steel beam bending, shear and lateral-torsional buckling, and steel tension members. Together with the reproduced classification and strut capacity tables it serves as a quick procedural reference, with the midas Gen implementation detailed in the companion Eurocode 2 and Eurocode 3 design guides.