This product-manual chapter documents the super element, a complex element containing many finite elements and equivalent to a substructure. In the MIDAS programs it was developed primarily to enhance modeling capability rather than only to reduce problem size, resolving the connectivity difficulties that arise where line elements meet planar elements. The chapter derives both the static condensation formulation and the dynamic condensation needed for dynamic analysis.
主要内容
Purpose of the Super Element
Substructuring is a long-established technique for reducing the size of a problem to be solved. In the MIDAS programs the super element procedure was developed instead to enhance modeling capability. Its practical role is to resolve connectivity difficulties at nodes where linear elements such as beams and columns meet planar elements such as shear walls and slabs.
Application to Shear Walls with Openings
A shear wall containing openings is finely meshed with planar elements to capture its behavior. The degrees of freedom of all nodes except those connected to beams and columns are then eliminated by static condensation, leaving a compact element with only the interface nodes exposed. This super element is used in the Residential Design System program.
Assembly and Partitioning
Constructing a super element begins by assembling the stiffness matrices and load vectors of the refined mesh in the ordinary finite element manner. The assembled system is then partitioned into terms associated with the super nodes that will remain and terms associated with the internal nodes that will be eliminated. This partitioning is the basis for the condensation.
Static Condensation
The internal degrees of freedom are expressed in terms of the retained degrees of freedom and the internal loads. Substituting that expression yields a reduced stiffness matrix and load vector expressed only in the retained degrees of freedom. These become the stiffness matrix and load vector of the super element for static analysis.
Dynamic Condensation
For dynamic analysis the equilibrium equation including mass must be condensed as well. Assuming the eliminated displacements follow from static condensation with zero load on those terms gives a transformation relating internal to retained displacements, and accelerations follow by differentiating twice with respect to time. Applying this transformation matrix and its transpose to the mass and stiffness matrices produces a condensed mass matrix while the condensed stiffness and load remain those of the static procedure.
The chapter shows that the MIDAS super element is a condensed substructure whose primary purpose is to make finely meshed shear walls and slabs connect cleanly to beam and column elements. Static condensation reduces the refined assembly to the interface degrees of freedom, and a corresponding transformation-based dynamic condensation produces the reduced mass matrix required when the substructure is used in dynamic analysis.