[EN_GEN] Post Tension Design_02 Design for PT system

PDF
·
12ページ
·
2.4MB
·
English
·
2025.03.12 更新
概要

The second part of the midas Gen post-tension series sets out the overall design flow chart and then covers the first two design activities in detail: selecting the tendon force and profile, and checking stresses at the initial and final service conditions. Allowable stresses for concrete and for prestressing steel are tabulated, the stress equations for a simple beam are derived, and a numerical example carries the procedure through to a strand count.

主要内容

01

Design Flow Chart for Post-Tension

The flow chart begins with choosing the concrete section and the tendon force and profile, then proceeds through checks of final stresses, initial stresses, deflections, prestress losses, flexural strength and shear strength, ending with anchorage steel design. Each failing check routes back to a specific remedy: adding rebar, adding shear steel, or changing the section. Laying the process out this way makes explicit which variable is adjusted when a particular check fails.

02

Tendon Profile Types

Three profile types are compared: straight, harped and parabolic. The parabolic profile is developed further, with guidance on how it is arranged along a span and how it appears after the transfer stage. The profile choice determines the equivalent upward load the tendon delivers and therefore the balanced load available to offset gravity load.

03

Allowable Stresses for Concrete

Limits are tabulated separately for the initial service condition, using the concrete strength at stressing, and for the final service condition, using the full design strength. Under initial load, extreme fibre compression and tension are limited, with a more generous tensile limit at the ends of simply supported members. Under service load, separate compressive limits apply for long-term service load and for prestress plus total load, together with an extreme fibre tensile limit.

04

Allowable Stresses for Tendons

Tendon stress is limited during stressing by the lesser of a fraction of the specified yield strength and a fraction of the specified tensile strength, and by a lower fraction of the tensile strength immediately after stressing. These limits bound the jacking force that can be delivered and hence the tendon area required. They are the counterpart of the concrete stress limits in setting the feasible design window.

05

Stress Equations for a Simple Beam

Top and bottom fibre stresses due to prestress are expressed through the section area, the eccentricity and the section moduli, condensed into top and bottom stress coefficients. Initial stresses combine the initial prestress effect with the self-weight moment and are checked against the initial tensile and compressive limits; final stresses combine the effective prestress with the applied load moments and are checked against the final limits. The note states explicitly which remedy each failure implies, either increasing the tendon area or enlarging the concrete section.

06

Bounding the Final Prestress Force

Minimum and maximum admissible values of the final prestress force are derived from the allowable tensile limit plus the applied moments and from the allowable initial compressive limit scaled by the ratio of final to initial prestress force. If the two bounds cross, the concrete section is inadequate and must be increased. This gives a direct feasibility test on the assumed section before any detailed checking.

07

Worked Example to a Strand Count

The example computes section area and centroid, moment of inertia, section moduli, the stress coefficients, self-weight and applied moments, and then the bounding prestress forces. From the governing final force and an assumed effective force per strand, the required number of strands per rib is obtained and rounded up. Both initial and final fibre stresses are then verified with the adopted force.

まとめ

Part two turns the post-tension design task into an ordered procedure with defined feedback paths, and shows how tendon force and profile follow from allowable stress limits at the initial and final service conditions. The bounding expressions for the final prestress force give an early test of section adequacy, and the worked example demonstrates the path from section properties to a practical strand count.