[EN_GEN] Eurocode2 Design Guide for midas Gen

PDF
·
125ページ
·
7.8MB
·
English
·
2025.03.11 更新
概要

This design guide explains how reinforced concrete design to Eurocode 2 (EN 1992-1-1:2004) is implemented inside midas Gen, and then demonstrates the complete workflow on a worked example. The first half is an algorithm reference covering material definition, ultimate limit state design for flexure, axial-flexure interaction and shear, serviceability limit state checks, and code detailing rules. The second half is a step-by-step tutorial that designs and checks a six-story reinforced concrete building, from model setup and design parameters through ULS member design, ULS member checking and SLS member checking. The document is intended both as an explanation of the design concepts and as a means of verifying the program's design output by hand.

主要内容

01

Scope, Materials and Design Information Setup

The opening chapter defines the design scope of the Eurocode 2 module and how concrete and reinforcement properties are established, including modulus of elasticity, Poisson's ratio, weight density and user-defined materials. It explains how design strengths of concrete and reinforcement are derived from characteristic strengths through partial safety factors, and how long-term versus short-term elasticity ratios are handled. It also covers the design information that must be supplied before a run: member assignment, unbraced lengths, live load reduction, geometric imperfections, P-Delta analysis, pattern loading and the selection of the design code, with persistent and transient design situations distinguished.

02

Ultimate Limit State: Flexure without Axial Force

The guide details the moment capacity calculation for beams using the rectangular stress block, describing how the stress block parameters and the neutral axis depth are established iteratively. The procedure determines the concrete compression force, checks whether the assumed neutral axis depth is consistent with equilibrium, computes the moment resistance and then reports a moment resistance ratio. Associated design criteria for rebar arrangement, concrete checking for beams with user-supplied rebar input, and the applicable design load combinations are described.

03

Ultimate Limit State: Axial Force with Bending

For columns and walls the guide explains slenderness ratio evaluation, the limiting slenderness value below which second-order effects may be neglected, and the magnification of design moments when that limit is exceeded. The eccentric axial load capacity is developed step by step: eccentricities for a biaxially loaded column, the concentric axial capacity, the contribution of the concrete stress block, the contribution of the reinforcement, the resulting axial-moment capacity pair, comparison of computed against actual eccentricity, and finally the P-M interaction curve check. Rebar design criteria and the separate rebar input required for column checking and wall checking are also covered.

04

Ultimate Limit State: Shear Design

Shear resistance is treated by distinguishing members that do not require design shear reinforcement from those that do, with the latter based on the variable-angle truss model given in Section 6.2.3 of EN 1992-1-1. The guide describes how the required shear reinforcement is derived, the design criteria applied to stirrups, how shear is verified in concrete code checking, and which load combinations govern. A verification chapter closes the ULS material by comparing program output with hand calculation.

05

Serviceability Limit State Checks

The SLS chapter defines serviceability-type load combinations and the serviceability parameters that must be set, then addresses three checks. Stress limitation covers limits on concrete and reinforcement stresses under the relevant combinations, with dead, live and other load cases treated separately. Crack width control is developed through the difference between mean strain in reinforcement and concrete and the maximum crack spacing. Deflection control and verification of results complete the chapter, with the guide noting that rebar data must be entered before any serviceability check can be run.

06

Detailing Rules for Beams, Columns and Walls

A dedicated chapter collects the EN 1992-1-1 detailing provisions that midas Gen applies automatically. For beams these include maximum and minimum main reinforcement ratios, minimum clear bar spacing and maximum stirrup spacing, with the relevant code clauses cited. Corresponding detailing rules for column design and for wall design, including minimum reinforcement requirements, are presented so that the user can see which constraints shape the automatically generated reinforcement.

07

Tutorial Model: Six-Story RC Building

The tutorial part introduces a six-story reinforced concrete building modeled with wall and beam elements, showing typical floor plan and sectional elevation. Loading comprises self weight, floor loads, wind loads to Eurocode 1-1-4 and seismic loads to Eurocode 8-1, with supports defined and linear static analysis performed. The tutorial walks through opening the model file, running the analysis, auto-generating Eurocode 2 concrete design load combinations, and setting the design code, frame bracing and sway conditions, effective length options, partial safety factors for materials, and concrete and rebar grades.

08

Design, Code Checking and Result Interpretation Workflow

The closing tutorial sections exercise the design and checking dialogs in sequence. Beam, column and wall design runs produce required reinforcement, spacing satisfying minimum bar spacing, biaxial P-M interaction diagrams and capacity ratios at the I-end, mid and J-end of each member, together with graphic, detail and summary output. The guide explains how to read flagged results, how to revise a section through the Section for Design dialog and re-run, how to update rebar data and then perform beam code checking, and finally how to run serviceability checking for stress limitation, crack control and deflection control on the same members.

まとめ

The document functions as a complete bridge between Eurocode 2 theory and its practical application in midas Gen, first laying out the implemented design algorithms in enough detail for hand verification, then proving them on a realistic multi-story RC building. Users finishing the guide should be able to configure Eurocode 2 design parameters correctly, run ULS and SLS design and checking for beams, columns and walls, and critically interpret and verify the program's reinforcement and capacity ratio output.

関連資料

同じカテゴリー・トピックから厳選した資料です。

STRUCTURE · TUTORIAL[EN_GEN] Steel Building Design as per EC3
STRUCTURE · TUTORIAL[EN_GEN] RC Building Design as per EC2
STRUCTURE · MIDAS NOTE[EN_GEN] Eurocode3 Design Guide for midas Gen
STRUCTURE · MIDAS NOTE[EN_GEN] Design Examples using midas Gen to Eurocode 3