This 2015 presentation documents the complete Eurocode design workflow in midas Gen, section by section. It covers the program's design scope and Eurocode implementation status, reinforced concrete frame and wall design, capacity design to Eurocode 8, meshed slab and wall design, steel code checking and optimal design, and the General Section Designer for arbitrary sections. Each part explains the relevant design parameters and the results the program produces.
主要内容
Design Scope and Eurocode Implementation Status
midas Gen offers steel code checking and optimal design, concrete code design and checking, capacity design, meshed slab and wall design and footing design, across a long list of national codes. The Eurocode implementation is itemised by part: concrete and steel material databases from Eurocode 2 and Eurocode 3, static wind load from Eurocode 1, static seismic load and response spectrum functions from Eurocode 8, load combinations from Eurocode 0, concrete and steel frame design for both ultimate and serviceability limit states, slab and wall design from Eurocode 2, and capacity design from Eurocode 8 and the Italian national code.
General Design Parameters
Effective length factors are computed automatically by evaluating the stiffness of every member framing into the joint at each end of a compression member, forming the stiffness ratio at each end, and solving the appropriate stability equation for braced or unbraced frames. The Member Assignment function lets several analysis elements be designed as one physical member, with the grouping displayable as a contour. Unbraced lengths for buckling about the strong and weak axes, and the laterally unbraced length used for lateral-torsional buckling, are calculated automatically from the member connectivity and support conditions once member assignment is defined.
Meshed Slab and Wall Design
Plate elements can be designed to Eurocode 2 for flexure and shear, with reinforcement directions that need not be orthogonal handled by the Wood-Armer formulation. The analysis plate moments about the local axes are transformed into the reinforcement directions using the angle between the local axis and the first reinforcement direction and the angle between the two reinforcement directions, and the Wood-Armer design moments follow. Flexural design outputs the rebar spacing and diameter, required area and ratio, resistance ratio and the Wood-Armer moment table, and the module also smooths moments and shears, generates wind and seismic loads for flexible floors, and applies local ductility detailing.
Punching and One-Way Shear Checks
Punching shear is checked at the critical perimeter around slab supports and at points of concentrated load, with the shear stress formed from the reaction, the perimeter and the effective depth including the eccentricity factor, and an alternative case taking the plate stress directly from the analysis. Where the demand exceeds the concrete resistance the required shear reinforcement per radial spacing is computed from the excess stress. One-way shear is checked along user-defined shear check lines, and detailed reports are generated for both.
Capacity Design to Eurocode 8
The seismic design sequence runs from performance requirements and ground conditions, through the seismic action and its combinations, the structural regularity criteria and the choice of analysis method among lateral force, modal response spectrum, pushover and inelastic time history analysis, to safety verification and capacity design with detailing. Capacity design is automated for beams, columns, walls and beam-column joints for the medium and high ductility classes of Eurocode 8 as well as the Italian and ACI ductility classes. Design moments in columns are derived from the beam moment resistances and the column seismic moment, capacity design shear forces on beams and columns are derived from the adjoining member moment resistances with the column resistance taken at the same axial force ratio on the interaction curve, and design envelopes are applied to bending moments in slender walls and to shear forces in the walls of dual systems.
Local Ductility Detailing
Detailing for local ductility is applied automatically, covering the maximum and minimum reinforcement ratio of the tension zone, the spacing of hoops within the critical region, and the mechanical volumetric ratio of the confining hoops in the critical regions. The ductility class is chosen by the user and the resulting design results can be checked against it. These provisions are what make the member capable of delivering the ductility assumed by the behaviour factor.
Steel Code Check and Optimal Design
Steel members are checked to Eurocode 3 for both ultimate and serviceability limit states. Steel Optimal Design searches the section database within a percentage band around the entered dimensions and verifies the strength of each candidate, reporting the average utilisation ratio of the selected members; a low average ratio indicates that the sections can be reduced and the optimisation repeated, and entering zero for the band searches all dimensions.
General Section Designer
The General Section Designer handles arbitrary cross sections in reinforced concrete, steel or composite construction, computing section properties, generating axial-moment and biaxial interaction curves and moment-curvature curves, calculating flexural capacity and the safety ratio against given member forces, and plotting stress contours. Shapes and rebar coordinates can be imported from AutoCAD drawing exchange files, and a live link with midas Gen or midas Civil imports the section shape, material properties and member forces for a chosen element and exports section properties back. Results from any page can be reported to a spreadsheet saved alongside the model file.
midas Gen implements the Eurocode chain end to end, from material and section databases and load generation through load combinations to reinforced concrete, steel, slab and wall design and Eurocode 8 capacity design with local ductility detailing. Supporting tools include automatic effective and unbraced length calculation, Wood-Armer based meshed slab design with punching shear checks, steel section optimisation, and the General Section Designer for irregular and composite sections.