This document explains the concept of bearing capacity in geotechnical engineering. It discusses the importance of foundation stability, bearing failure mechanisms, and calculation methods for ultimate and allowable bearing capacity.
핵심 내용
1. What is Bearing Capacity?
Bearing capacity is the maximum load per unit area that the ground can support through a foundation. If the applied load exceeds this capacity, structural failure or excessive settlement may occur.
2. Types of Foundations
Foundations are classified into shallow and deep foundations based on depth and load distribution characteristics. Examples include mat foundations, pile foundations, and specialized footings such as conical shell and inverted dome foundations.
3. Design Requirements for Foundations
Foundations must be designed to prevent shear failure and excessive settlement. The ultimate bearing capacity is the soil’s failure limit, while allowable settlement criteria ensure long-term structural performance.
4. Methods for Calculating Bearing Capacity
There are three primary methods for determining bearing capacity: (1) Theoretical bearing capacity equations (Terzaghi, Meyerhof), (2) Plate load tests, and (3) Numerical analysis using FEM. Each method has advantages and limitations based on soil conditions and structural requirements.
5. Plate Load Test for Bearing Capacity Assessment
The plate load test measures load-settlement behavior of the soil in the field. A circular or square plate is loaded incrementally, and ultimate bearing capacity is determined from the load-settlement curve.
6. Example: Numerical Analysis of a Continuous Foundation
A continuous foundation is analyzed using FEM, applying the Mohr-Coulomb constitutive model. Boundary conditions and load cases are defined, and results are compared with Terzaghi and Meyerhof equations.
7. Comparison of Numerical and Analytical Results
Theoretical calculations (Terzaghi and Meyerhof) estimate a bearing capacity of 540 kN/m², while FEM analysis results in 587 kN/m², showing an 8.7% deviation due to modeling assumptions.
Bearing capacity analysis is essential for foundation design to prevent structural failure. While theoretical equations provide quick estimates, numerical analysis using FEM offers a more realistic evaluation of soil behavior and foundation performance.