[EN_GEN] Seismic Specific Functionality in midas Gen_FEMA

PDF
·
30페이지
·
2.7MB
·
English
·
2025.03.12 업데이트
요약

This MIDAS technical note surveys the seismic analysis and design features of midas Gen, organised around the FEMA seismic rehabilitation framework. It moves from the overall rehabilitation decision flow and the selection of an analysis procedure, through pushover analysis and the capacity spectrum method, to static seismic design, base isolators and dampers, mass and damping definition, modal and response spectrum analysis, and fiber element analysis. Each section links the code concept to the corresponding modelling step or dialog in the program.

핵심 내용

01

FEMA Seismic Rehabilitation Flow

The document lays out the rehabilitation process as a sequence: review initial considerations, select a rehabilitation objective, choose an initial risk-mitigation approach, perform systematic rehabilitation, design the intervention and verify the measures. Initial considerations cover structural characteristics such as configuration, detailing, material strength and foundation interconnection, alongside site seismic hazards including ground shaking, landslide, liquefaction and settlement. The rehabilitation objective is expressed in terms of a target performance level.

02

Choosing Between Linear and Nonlinear Procedures

The demand-capacity ratio, formed from the force due to gravity plus earthquake loads against the expected component strength, is used as the screening criterion for the analysis procedure. Below the threshold a linear procedure is acceptable, above it a nonlinear procedure is required when certain irregularities are present. The triggering irregularities listed are in-plane and out-of-plane discontinuity in a primary lateral-force-resisting element and severe weak-story irregularity in any direction.

03

Pushover Analysis Workflow in midas Gen

Pushover analysis subjects the structure to incrementally increasing lateral load and records the sequence of cracking, yielding, plastic hinge formation and failure. The midas Gen workflow is presented as a chain of steps: pushover global control, defining lateral loads, defining and assigning hinge properties, running the analysis, checking the pushover curve and target displacement, reviewing hinge status and finally verifying safety. Its advantages are described as revealing overall structural behavior, exposing the order of hinge formation, and allowing selective strengthening of only the deficient members during rehabilitation.

04

Capacity Spectrum Method

Following FEMA-273, the capacity curve obtained from pushover analysis is converted and overlaid against a demand spectrum. The intersection defines the performance point, from which the expected displacement and component demands are read. This gives the link between the nonlinear static analysis result and the performance level selected as the rehabilitation objective.

05

Base Isolators and Dampers

Seismic isolation is introduced with the objective of improving performance at all hazard levels by limiting interruption of use, reducing damaging deformation in structural and nonstructural components, and reducing acceleration response. midas Gen supports several isolator types and damper types, including viscoelastic and hysteretic system dampers. Result output includes hysteretic loops for the isolator elements and time history comparisons of story shear and displacement response with and without isolation.

06

Mass and Damping Modelling Options

Mass can be entered as nodal masses, floor diaphragm masses, loads converted to masses, or self-weight converted to mass, and the formulation can be lumped or consistent. Structure type settings control which degrees of freedom carry mass. Damping may be specified modally, as mass and stiffness proportional (Rayleigh) damping, or as strain energy proportional damping in which modal damping ratios are assembled automatically from damping ratios assigned to element and boundary groups.

07

Modal and Response Spectrum Analysis

Three eigen solution options are described: subspace iteration for large finite element systems, Lanczos for efficient extraction of lower modes, and load-dependent Ritz vectors which reflect the spatial distribution of the dynamic loading and give reliable results with fewer modes. Response spectrum analysis treats the multi-degree-of-freedom response as a combination of single-degree-of-freedom responses drawn from a smoothed design spectrum. The procedure runs from defining spectrum functions, to setting up load cases, to reviewing results, and includes an automatic search for the building principal axes.

08

Fiber Element Analysis

Fiber analysis divides the cross section into cells, each with its own inelastic stress-strain relationship, so that axial-flexural interaction is captured directly. The note cites the Kent and Park model for concrete and the Menegotto-Pinto model for reinforcing steel. Results can be plotted at the fiber cell level to inspect the local strain state of a section.

정리

The note presents midas Gen as covering the full seismic workflow implied by the FEMA framework, from screening with demand-capacity ratios through nonlinear static and dynamic evaluation to the design of isolation and damping systems. Pushover analysis with the capacity spectrum method is positioned as the central tool for performance-based evaluation and targeted rehabilitation. Supporting capabilities in mass and damping definition, eigen solution methods and fiber sections give the modelling fidelity these procedures require.

관련 자료