This conference presentation, delivered by MIDAS IT in Krakow in 2014, lays out the complete procedure for designing a reinforced concrete building to Eurocode 2. It moves from the general building analysis workflow, through the code considerations that must be settled before design, into the ultimate limit state section checks and the serviceability limit state, and closes with a consolidated procedure table and a midas Gen demonstration. Its organising idea is that Eurocode designs for effects rather than for member types.
핵심 내용
Building Design Workflow
The overall sequence runs from the architectural concept design to a structural solution, then applying loads, performing the structural analysis, forming combinations of actions, designing the structural elements and finally producing project documentation. Presenting the workflow first establishes where the code checks sit within the wider project. Everything that follows elaborates one of these stages.
Design Life and Durability
The design life must be established because durability requirements, including concrete deterioration and fatigue, follow from it. Durability is then assured through the exposure class and the associated cover and material requirements. This is treated as a prerequisite decision rather than a detailing afterthought.
Actions and Combinations of Actions
Permanent and variable actions, wind, seismic and dynamic loads must be applied and then combined according to the Eurocode combination rules. The combinations differ between the ultimate and the serviceability limit states, so both sets must be generated. This is one of the five general considerations the presentation identifies as needing resolution before any section is checked.
Method of Analysis and Moment Redistribution
Eurocode permits and gives specifications for moment redistribution, which changes the distribution of design moments away from the elastic result. For flat slabs any proven method may be used, and the presentation lists grillage models, finite elements, the yield line method and the equivalent frame method as acceptable alternatives. The freedom to choose the analysis method is paired with the obligation to justify it.
Material Properties and Higher Concrete Classes
Concrete is specified by cylinder compressive strength and classes are available well beyond ordinary strengths, with the code splitting its provisions at a threshold class above which special rules apply. Reinforcement is classified by ductility class. Choosing a concrete class above the threshold therefore changes the applicable design expressions, not merely the strength value.
Stability and Imperfections
Geometric imperfections must be accounted for in the analysis, and overall stability must be verified. Together with the requirement to assure ductile failure, these represent the structural safety considerations that sit outside individual section capacity. The presentation flags imperfections explicitly as a mandatory rather than optional allowance.
Section Design for Effects
Design covers beams, columns, slabs, walls and foundations, and in each case the checks are organised by effect: bending, bending with axial force, shear, torsion and punching shear. Bending with axial force is resolved through the section's axial-moment interaction curve, and slenderness and second order effects can be handled by simplified methods such as nominal curvature. The panel zone effect is also addressed as part of the section design discussion.
Shear Design Flow and Serviceability
Shear design follows a decision flow: compute the resistance without shear reinforcement and, if the demand is below it, provide only nominal reinforcement; otherwise check the demand against the maximum capacity, increasing the strut angle or the section size if it is exceeded, and then size the shear reinforcement. Punching shear is treated separately for slabs. At the serviceability limit state, deflection is limited to a fraction of the span for appearance and general utility and to a tighter fraction where damage to adjacent parts is a concern, verified either by calculating the actual deflection or by satisfying a limiting span-to-depth ratio, with more severe limits possible depending on building function and adjacent elements.
The presentation frames Eurocode 2 building design as a sequence of settled general decisions, namely design life and durability, actions and combinations, analysis method and redistribution, material class and imperfections, followed by section checks organised by effect rather than by member type, and finally serviceability verification. Its consolidated summary table maps the whole process onto slab, beam, column and wall design and onto the documentation deliverables, with midas Gen demonstrated as the tool that executes it.