[EN_GEN] Pushover analysis in midas Gen_S03 Introduction of Capacity Spectrum Method

PDF
·
10페이지
·
1.2MB
·
English
·
2025.03.11 업데이트
요약

The third part of the midas Gen pushover series sets out the capacity spectrum method step by step. The method compares the capacity of the structure, expressed as a load-deflection curve, with the demand, expressed as response spectra, and takes their intersection as the estimated response. Nonlinear behavior is represented by linear response spectra computed for increased damping ratios, so the whole assessment is performed with equivalent linear tools.

핵심 내용

01

Step 1 and 2: Capacity Curve to Capacity Spectrum

A pushover analysis first produces the capacity curve of the multi degree of freedom system as base shear against roof displacement. That curve is then converted to a capacity spectrum for an equivalent single degree of freedom system, giving spectral acceleration against spectral displacement. In midas Gen the conversion is carried out using the first mode, through a modal participation factor and a modal mass coefficient computed from the storey masses and mode shape.

02

Step 3: Converting the Demand to ADRS Format

The design response spectrum, normally given as spectral acceleration against period, is transformed into acceleration-displacement response spectrum format so that it can be plotted on the same axes as the capacity spectrum. The transformation relates spectral displacement to spectral acceleration through the square of the period. Lines of constant period then appear as radial lines on the ADRS plot.

03

Step 4: Equivalent Damping

Equivalent viscous damping is derived from the ratio of the energy dissipated by the structure to its maximum strain energy, evaluated from the areas enclosed by the hysteresis loop and by the corresponding elastic triangle on the capacity spectrum. The bilinear idealisation of the capacity spectrum, defined by its yield and peak points, supplies the areas needed. The effective damping is the sum of this hysteretic contribution and the inherent damping of the structure.

04

Step 5: Iterating to the Performance Point

The capacity and demand spectra are first plotted with the conventional elastic damping and their intersection gives trial spectral displacement and acceleration. The equivalent damping implied by that point is computed, the demand spectrum is redrawn at that damping, and a new intersection is found; the cycle repeats until the equivalent damping converges. The converged spectral displacement is the performance point, the maximum displacement demand for that hazard level.

05

Step 6 and 7: Back to the Real Structure and Acceptance Checks

The performance point is converted back to the multi degree of freedom system by inverting the step two transformation, yielding the roof displacement and base shear at the performance point. Story drift and member deformation are then checked at that state. The performance objective is considered satisfied only when both the story drift and the member deformations lie within the allowable values for the target performance level.

06

Acceptance Criteria and Performance Levels

Allowable rotation and short-term story drift limits are tabulated against the performance levels from fully operational, through operational and life safety, to near collapse, with the corresponding damage descriptions from negligible to serious. Member deformation is judged against the allowable values given in the governing standard, using the force-deformation relationship with performance levels defined in FEMA 356. This links the analytical performance point to a stated damage state.

07

Defining Inelastic Hinge Properties

Inelastic hinges must be set at the members, using modeling parameters such as those tabulated in FEMA 356 for reinforced concrete beams, which define the plastic rotation limits and residual strength of the hinge. The note states explicitly that midas Gen does not generate hinge properties automatically from a standard, so they must be entered manually. This is a significant practical burden and a source of error if neglected.

08

Reducing Initial Member Stiffness for Cracking

Because the inelastic hinge model does not itself represent cracking, the reduction of section stiffness due to cracks caused by gravity and lateral load must be built into the analysis model. ATC-40 tabulates effective flexural, shear and axial rigidities as fractions of the gross values, distinguishing non-prestressed from prestressed beams, columns in compression from columns in tension, and uncracked from cracked walls. National standards may be followed instead, or a precisely computed cracked stiffness may be used where it has been evaluated.

정리

The capacity spectrum method converts a pushover capacity curve into an equivalent single degree of freedom capacity spectrum, plots it against a demand spectrum in acceleration-displacement coordinates, and iterates on equivalent damping until the performance point converges. Acceptance requires both story drift and member deformation at that point to satisfy the target performance level, and because midas Gen does not create hinge properties automatically and cracking is not captured by the hinge model, manual hinge definition and effective stiffness reduction are essential preparation.