[EN_GEN] High-rise building design_S05 SHM (Structural Health Monitoring)

PDF
·
8페이지
·
1.6MB
·
English
·
2025.03.11 업데이트
요약

This fifth instalment of the high-rise design series covers structural health monitoring, an integrated system that measures a building in real time to assess its safety objectively and extend its service life. It describes the four units that make up such a system, the external excitations and structural responses that are measured, and then focuses on the three tasks that fall to the structural engineer: choosing where to install instruments, building a damage estimation system, and setting the alarm levels.

핵심 내용

01

What Structural Health Monitoring Provides

The stated benefits are relieving public anxiety about tall buildings, economising on routine safety inspection through continuous monitoring, minimising accident risk by allowing an appropriate response during earthquakes, typhoons and other extreme events, maximising the building's service life, and feeding characteristics of the real structure back into design guidelines. The system is defined as monitoring in real time using advanced measurement technology so that safety is evaluated objectively and maintenance is managed quantitatively.

02

The Four Units of the System

The measuring unit records both external stimulation, namely wind force and earthquake acceleration, and structural response, namely displacement and acceleration. The transferring unit is either a wired system requiring wiring planning or a wireless system requiring network planning. The analysing unit builds the database and performs detailed analysis of the measured data, and the alarming unit reports the condition of the structure and raises hazard alerts to the user, together forming a real-time analysis and notification system.

03

What Is Actually Measured

External stimulation monitoring covers wind direction and speed measured at roof level, seismic ground acceleration measured at the base, and damper motion, the latter used to evaluate the dynamic characteristics and performance of vibration control devices and to tune them. Structural response monitoring covers building displacement and acceleration for behaviour, wind vibration and dynamic characteristics, stress in the main members to assess their utilisation under external force, floor vibration for serviceability assessment, and the shortening of vertical concrete members.

04

Choosing Instrument Locations for Stress Measurement

Stress gauges must be placed where damage is expected, so the engineer first identifies the members that would fail by inelastic analysis such as pushover or time history analysis under increasing lateral load, using the wind and earthquake dynamic data. A finite element analysis of the identified members then determines the local position within the member where damage would concentrate. Instrument locations follow from that two-level search rather than from a uniform grid.

05

Choosing Instrument Locations for Acceleration Measurement

Accelerometer positions are chosen so that the measured data can reconstruct the mode shapes, which is done by eigenvalue analysis of the model to determine the most efficient number and placement of sensors for capturing the principal modes. The presentation compares mode shapes derived from the analysis model with those reconstructed from measurement for the first three modes, in elevation and in plan. Getting this placement right is what makes later frequency-based damage detection possible.

06

Damage Estimation System

A damage scenario database is built in advance by reducing the stiffness of a candidate damaged member in the analysis model, running an eigenvalue analysis, extracting the resulting mode shapes and frequencies and storing them as a scenario. When an event occurs, the natural frequency measured by the monitoring system is compared with the analysis frequency and the model is adjusted to match the measured period, then the measured dynamic properties are matched against the database to infer which member is damaged. If an instrument is present on the predicted member its damage level is checked directly, and the process ends in a diagnosis, report and alarm; if the properties indicate no change the structure is declared safe.

07

Alarm System and Levels

Alarms are defined both for external loads, when the wind speed or earthquake acceleration exceeds the design value, and for structural response, when the change in natural frequency exceeds an allowable ratio, the roof displacement exceeds an allowable value, or concrete or steel stress exceeds a threshold. Four levels are used in general, safety, caution, warning and danger. For roof lateral displacement the levels are tied to the state of the structure, from all members elastic, through yielding of the core coupling beams, to yielding of the special system such as outriggers and mega braces, and finally its failure; for compression stress in a steel member the levels are tied to the buckling strength with and without the strength reduction factor and to the yield strength, while strain is monitored on a simpler two-level scheme.

정리

Structural health monitoring of a tall building combines measuring, transferring, analysing and alarming units to track wind and seismic input alongside displacement, acceleration, member stress, floor vibration and vertical shortening. The engineering work lies in placing instruments where inelastic and finite element analyses predict damage and where eigenvalue analysis makes mode reconstruction possible, in building a damage scenario database against which measured frequencies can be matched, and in tying four-level alarms to identifiable structural states.

관련 자료

같은 카테고리와 주제에서 선별한 자료입니다.

STRUCTURE · EXPERT COLUMN[KR_김두기.2010] 24_[유지관리] 구조물의 건전성 모니터링(SHM)과 평가
STRUCTURE · SEMINAR[KR_2011.06] Part.2 Structural Health Monitoring_초고층,수상구조물,대공간(김지영)
STRUCTURE · SEMINAR[KR_2011.06] Part.1 구조물의 헬스모니터링의 소개 및 적용사례(유은종)
STRUCTURE · SEMINAR[KR_2009.11] Part 1. MIDAS NFX-상세해석의 이해와 활용