This is the first instalment of a seven-part series on the main technologies of high-rise building design with midas Gen. It defines what counts as a high-rise building, maps out the technologies the series will cover, and then concentrates on economical structural design: how construction cost grows with height, where the cost actually sits in a concrete frame, how to choose the floor system, and what column arrangement gives the most lateral stiffness for a given quantity of material. Note that the folder title does not match the content, which is the series introduction rather than construction stage analysis.
핵심 내용
What Counts as a High-Rise Building
Three definitions are offered: a slenderness ratio of five or more, the international associations' threshold of roughly fifty stories or two hundred metres, and Mark Fintel's engineering definition of a building that requires a special structural system to resist lateral load. The last is the operative one for the series, because it is the lateral system rather than the height itself that changes the design problem.
Map of High-Rise Technologies
The series covers eight technology areas: selecting the optimal structural system through case study, lateral displacement control through plan shape and member stiffness, wind vibration control including tuned mass, tuned liquid and active mass dampers, prediction of column shortening with precision calibration and measurement management, prevention of progressive collapse through joint detailing and design technique, structural health monitoring for hazard detection and damage prediction, control of joints against cracking from relative shortening, and control of hydration heat in mass concrete. Each of the later instalments takes up one of these.
How Construction Cost Grows with Height
Three curves are compared: one showing that the unit-area construction cost of a hundred-story building is several times that of a ten-story building once lateral force is included, one showing the gradual cost rise from columns growing with the number of stories, and one for the weight of the horizontal system of slabs and beams. The gap between the first two curves is the added frame weight attributable to wind load alone. An optimum system is identified where the combined vertical and lateral weight is minimised, and anything above it is uneconomical structural weight.
Where the Cost Sits in a Concrete Frame
A breakdown of conventional reinforced concrete frame construction cost shows that formwork accounts for roughly half of the total and that formwork labour alone is the single largest item, far exceeding formwork material. Concrete and reinforcement material and labour make up the remainder in smaller shares. The conclusion drawn is that reducing formwork, not concrete or steel quantity, is where the economy in a concrete high-rise lies, which in turn favours floor systems that minimise formwork area and construction cycle.
Choosing the Floor System
Concrete and steel floor options are compared on floor height and construction cycle. The conventional beam and girder concrete system is the most common but suits relatively short spans and needs the longest cycle, whereas flat slab and post-tensioned slab systems cut the floor height by a few hundred millimetres per floor, minimise formwork area and are easily systemised on a shorter cycle. On the steel side, metal deck systems are the common baseline, and composite truss and slim floor systems reduce floor height further; the best options are cited as cutting formwork area and construction period substantially.
Benchmarking Quantities Against Other Towers
Concrete volume and reinforcement weight per unit floor area are plotted for a set of well-known towers including the Burj Khalifa, Taipei 101, Trump Tower and a Korean project, alongside the project under study before and after improvement. The comparison is presented as the way to test whether a proposed special lateral system is economically justified, since absolute quantities mean little without a peer benchmark.
Efficient Column Arrangement and Rigidity Indices
For lateral stiffness the ideal arrangement concentrates columns at the plan edges rather than spacing them equally, since the moment of inertia about the neutral axis depends on how far the columns sit from it. A bending rigidity index normalised to a corner-concentrated arrangement is tabulated for historic and modern configurations including framed tube and edge-plus-core layouts, and a shear rigidity index normalised to a wall system is tabulated for diagonal web and conventional bracing arrangements. For a rigidly jointed tube the shear rigidity rises as the member spacing narrows, and the practical aim is a structural plan as close to the ideal arrangement as the architectural plan permits.
A high-rise is best defined by its need for a special lateral system, and the dominant design driver is economy: cost per unit area rises steeply with height because of lateral load, and in concrete frames formwork labour is the largest single cost. Choosing a floor system that minimises formwork and cycle time, benchmarking quantities against comparable towers, and arranging columns toward the plan edges to maximise the bending and shear rigidity indices are the levers available before any special lateral system is chosen.