This technical note explains how midas handles section offset for beams that sit below a floor slab, and what the resulting analysis output looks like. It shows that offset is realized internally by generating a rigid body element equal to the offset distance, and compares moment and axial force results with and without offset. The note also warns about the apparent loss of moment equilibrium and the sawtooth moment diagram that can appear when offsets are combined with a meshed slab.
핵심 내용
How Section Offset Is Modelled
Because a beam is normally installed below the floor, analysis is performed with the section center placed at the top rather than at the center of the beam. To realize this eccentricity midas internally creates a rigid body element spanning the offset distance. The overall analysis results from the center-center and center-top configurations remain broadly comparable.
Sawtooth Moment Diagram with Meshed Slabs
When section offset is applied to a beam framing into a slab that has been meshed, the resulting moment diagram can take on a sawtooth shape. This artifact is caused by the influence of the internally generated rigid elements rather than by real structural behavior. Recognizing its origin prevents misinterpretation of the diagram.
T-Beam Action and Reduced Beam Moment
Without section offset the slab is centered on the beam, so a larger moment is generated in the beam itself. With section offset the slab sits on top of the beam and the analysis effectively captures T-shaped beam behavior, which reduces the beam moment relatively. This makes the offset model closer to the physical composite action of a slab-and-beam floor.
Slab Axial Force and Reinforcement Design
In the non-offset model the moment is simply distributed according to the relative stiffness of slab and beam. In the offset model the eccentric geometry generates axial force in the slab, with compression and tension zones appearing across the slab. This axial force can then be taken into account when designing the slab reinforcement.
Apparent Loss of Member Force Equilibrium
Without section offset a moment equilibrium check on the joint balances directly from the reported member forces. With section offset the equilibrium value cannot be reproduced from the visible results, because the deflection and force carried by the invisible internal rigid element are not displayed. Equilibrium is nevertheless satisfied internally, so the discrepancy is a reporting artifact rather than an analysis error.
The note establishes that section offset in midas is implemented through internally generated rigid elements, which correctly captures T-beam action, lowers the beam moment and introduces design-relevant axial force in the slab. It also explains the two side effects users should expect: sawtooth moment diagrams when offsets meet meshed slabs, and joint moment equilibrium that cannot be verified from the visible member forces alone.