This fourth instalment of the high-rise design series covers wind resistant design of tall buildings. It explains the aerodynamic phenomena that make code wind loads insufficient for a tall flexible building, describes the three types of wind tunnel test and what each produces, compares the wind response of different plan shapes and building configurations, and sets out the aerodynamic, structural and damper-based routes to controlling wind vibration.
Key Topics
Wind Effects Specific to Tall Buildings
Three phenomena are distinguished: turbulence generated as flow separates around the building, the Venturi effect where air accelerates through a gap between buildings, and gust pressures faster than the mean wind speed whose effect grows with the flexibility of the structure. Turbulence and the Venturi effect together mean the real wind load can differ substantially from the code-calculated value. Vortex shedding produces displacement across the wind direction that in a tall building can exceed the along-wind displacement, with biaxial response arising from plan asymmetry and from the pressure wake along the sides of the building.
The Three Wind Tunnel Tests
A wind force test verifies safety and serviceability against wind vibration and supplies design wind loads, producing aerodynamic force coefficients, wind load spectra, vibration displacements and base shear, overturning and torsional moments. A wind pressure test investigates the local pressures on the building surface and supplies the pressure coefficients, in maximum, minimum and average form, used for cladding and canopy design. A wind environment test assesses pedestrian comfort and safety around the base, expressed as wind speed ratios and the frequency of wind speeds and directions, with visualisation of the flow.
Influence of Plan Shape
Mean along-wind and across-wind overturning moment coefficients are compared for a range of plan shapes evaluated at equal floor area, with the square plan as the reference. The comparison, taken from published research on the aerodynamic characteristics of tall buildings with unconventional configurations, shows that plan shape alone changes the overturning demand appreciably. This makes the plan a wind design variable and not only an architectural one.
Influence of Overall Configuration
The same coefficients are compared across unconventional building configurations, including helical forms and buildings with chamfered or cut corners. Helical and corner-modified forms are shown to reduce the wind-induced response relative to the plain square prism, because they disrupt the coherent vortex shedding that drives the across-wind response. The comparison is drawn from the same body of wind tunnel research.
Structural Routes to Controlling Vibration
Increasing the generalised mass of the structure reduces both displacement and acceleration but raises the seismic load, so it must be applied with care. Increasing the stiffness reduces the vibration amplitude directly. Changing the structural material between steel and concrete alters both damping and stiffness and so is another available control.
Aerodynamic Design and Layout
Wind response can also be reduced without adding structure, by changing the building layout to avoid wake buffeting from an upstream building, and by modifying the building shape, for example providing an opening near the top, to reduce vibration in the along-wind direction. These aerodynamic measures act on the excitation rather than on the response, so they are most effective if adopted early in the design.
Vibration Control Devices
A table of damper types covers the tuned mass damper as a passive device using a moving mass, the hybrid mass damper combining passive and active control, the fully active mass damper, tuned liquid and tuned liquid column dampers that control vibration through the motion of a liquid mass, and other devices such as oil and viscous dampers. Measured accelerations from a project are compared before and after installation of a tuned mass damper against the acceptable value from the international comfort standard, and the wind vibration is reported as reduced by roughly forty to fifty percent.
Wind design of a tall building cannot rest on code loads alone, because turbulence, Venturi acceleration, gusts and vortex shedding produce demands and across-wind responses the code does not capture; wind force, pressure and environment tunnel tests supply the missing information. Response is then controlled through plan and configuration choices such as helical forms and corner modifications, through mass, stiffness and material decisions, and through mass or liquid dampers, which measured project data shows can roughly halve wind-induced acceleration.