[EN_GEN] Pushover & TH_S03 TH Tutorial for evaluation of machine vibration

PDF
·
18 pages
·
1.9MB
·
English
·
Updated 2025.03.11
Summary

The third part of the midas Gen time-history series is a tutorial on evaluating the vibration of a floor slab excited by walking. Although the series index labels this part as machine vibration, the worked example follows a person walking across a steel-framed residential floor. It covers partial modeling of the target bay, boundary conditions, mass conversion, identification of the slab modes, construction of the walking load function, assignment of the load along a walking path and interpretation of the resulting response.

Key Topics

01

Model Description

The example is a five-story steel frame residential building of moderate height, designed to AISC-LRFD, with H-section columns and several beam and girder sizes and a thin concrete slab. Gravity loading comprises self-weight plus a superimposed dead load and a live load. The structural system is ordinary, so the vibration behavior is governed by the slab and its supporting beams rather than by the frame.

02

Partial Modeling Strategy

Because only the period of the target slab matters, the whole building is not modeled; instead roughly half of the slabs and beams adjacent to the target panel are included. Nodes are created in advance at the intended walking positions so that they are retained when the slab mesh is generated. Rigid links are applied at the slab over the column cross-section so that the local support condition is represented correctly.

03

Converting Loads to Mass

Gravity loads are entered as pressure loads and then converted into mass, with the conversion restricted to the vertical direction for a floor vibration study. Live load is included in the mass where it represents items fixed to the floor such as partitions and desks. Because the response is dominated by resonance, the participating mass determines the modal frequencies that follow.

04

Identifying the Slab Modes

An eigenvalue analysis is run and the modes that actually deform the target slab are picked out, with their frequencies and periods tabulated. In the example four modes influence the slab, spanning a range of frequencies. These modes govern both the choice of excitation frequency and the analysis time step.

05

Choosing the Walking Load Frequency

Normal walking excitation lies in a narrow low frequency band, well below the fundamental frequency of a stiff floor. To produce the worst case, the walking frequency is selected so that the slab's fundamental frequency is an integer multiple of it, putting the floor into resonance with a harmonic of the walking load. This gives a deliberately conservative excitation rather than an arbitrary one.

06

Choosing the Time Increment

The time increment must be small enough to capture every mode included in the analysis. The guidance given is to take a small fraction of the shortest period among the modes considered, which keeps the analysis both accurate and efficient. This value is then reused when the load function is built and when the load case is defined.

07

Assigning the Load along a Walking Path

The load is applied at a sequence of nodes representing successive footfall positions across the slab, each with its own arrival time spaced by the walking period, and with a negative scale factor since it acts downward. The procedure is repeated for every point along the path before the analysis is performed. Modeling the moving load this way captures the build-up of response as the walker crosses the panel.

08

Locating the Critical Node and Reading Results

Maximum and minimum accelerations are listed for the slab nodes relative to the ground so that the node with the largest response can be identified. Graph functions for displacement and acceleration in the vertical direction are then defined against time for that node. The peak values and the frequency at which they occur are read from the graphs and compared against vibration serviceability criteria.

Conclusion

The tutorial shows how a floor vibration serviceability check is set up as a linear modal time-history analysis in midas Gen: model only the relevant bay, convert gravity load to vertical mass, find the slab modes, then tune the walking frequency to resonate with the fundamental mode and march a footfall load across the panel. The critical node is located from the acceleration extremes, and its displacement and acceleration histories provide the values assessed against comfort criteria.

Related Resources

Hand-picked materials in the same category and topic to deepen your workflow.