This midas Note presents the seismic-specific capabilities of midas Gen organised around the Eurocode 8 workflow. It follows two design flowcharts, one for new buildings and one for the assessment of existing buildings, and then describes the supporting modelling features: base isolators and dampers, mass definition, damping formulations, modal analysis solvers and fiber analysis. Each step of the code procedure is mapped onto the corresponding program function.
Key Topics
Seismic Design Flowchart for New Buildings
The design sequence runs from performance requirements and ground conditions through the definition and combination of seismic action, the check of structural regularity, the seismic analysis itself, safety verification and finally capacity design and detailing. Regularity in plan and elevation determines which of the four permitted analysis methods may be used. The permitted methods are the lateral force method, modal response spectrum analysis, pushover analysis and inelastic time history analysis.
Performance Requirements and Compliance Criteria
Eurocode 8 sets a no-collapse requirement at the reference return period and a damage limitation requirement at a much shorter return period. Ultimate limit state compliance requires checking resistance and energy dissipation capacity at global level, covering overturning and sliding, and at member level, with plastic rotation for ductile components and resistance for brittle ones. Damage limitation is checked through inter-story drift at global level and resistance at member level.
Representation and Combination of Seismic Action
Seismic action is represented either by elastic and design response spectra, horizontal and vertical, with the behaviour factor q applied to obtain the design spectra, or by time histories. Importance classes scale the reference ground acceleration. Directional combination uses the 100:30 rule, extended to three components when the vertical direction is included, on top of the combination with permanent and variable loads.
Safety Verification and Capacity Design
Ultimate limit state verification covers member resistance, the global and local ductility condition expressed as a strength hierarchy between columns and beams, equilibrium against overturning and sliding, and the resistance of horizontal diaphragms, foundations and seismic joints. Capacity design forces are then derived for beams and columns from the beam moment resistances rather than from the analysis forces. Design envelopes are applied to bending moments and shear forces in slender walls and in the walls of dual systems.
Assessment of Existing Buildings
For existing structures the flowchart replaces the performance requirement step with three performance levels, near collapse, significant damage and damage limitation, each associated with a different return period, and introduces knowledge levels that reflect the amount of available information. Compliance criteria are expressed separately for ductile components, in terms of deformation, and for brittle components, in terms of strength. The result feeds a decision on whether structural intervention is required.
Pushover Analysis Workflow
Pushover analysis is used to verify or revise the overstrength ratio, to estimate the expected plastic mechanism and damage distribution, to assess existing or retrofitted buildings, and as an alternative to behaviour-factor-based linear design. In midas Gen the process runs from pushover global control and lateral load definition, through hinge property definition and assignment, to the analysis, the pushover curve and target displacement, the hinge status check and the final safety verification.
Mass, Damping and Modal Analysis Options
Mass can be entered as nodal masses, floor diaphragm masses, loads converted to masses or self-weight converted to mass, and treated as lumped or consistent mass. Damping can be defined modally, as mass and stiffness proportional damping, or as strain energy proportional damping assembled from element and boundary group damping ratios. Eigenvalue extraction offers subspace iteration for large systems and Lanczos for lower modes, while load-dependent Ritz vectors give reliable dynamic results with fewer modes.
Base Isolators, Dampers and Fiber Analysis
Base isolation and damping devices are supported as nonlinear link elements and their behaviour is examined through time history analysis results. Fiber analysis divides a section into cells with inelastic stress-strain material laws, such as the Kent and Park model for concrete and the Menegotto-Pinto model for steel. Fiber cell results can be plotted to trace the progression of inelasticity within a section.
The note demonstrates that midas Gen covers the complete Eurocode 8 route for both new and existing buildings, from the definition of seismic action to capacity design and detailing. Its combination of linear and nonlinear analysis methods, flexible mass and damping definitions, and device- and fiber-level modelling allows an engineer to stay within one program from code compliance checks to detailed performance assessment.