This MIDAS Note explains how midas Gen computes the long-term deflection of a two-way slab modelled with meshed plate elements, and how to run the check. It sets out the code basis for scaling immediate deflection into time-dependent deflection, describes the iterative cracked-section algorithm used to obtain the effective stiffness, and then gives two tutorials: one for the long-term deflection under sustained load and one for the total deflection formed by adding the long-term and immediate components.
Key Topics
Immediate and Long-Term Deflection
Deflection of a two-way slab divides into immediate, or elastic, deflection occurring as soon as the load is applied, and long-term deflection developing over time from creep and drying shrinkage of the concrete. Unless a more comprehensive analysis is performed, the code allows the additional time-dependent deflection to be computed as the immediate deflection under sustained load multiplied by a long-term factor. The permissible calculated deflection limits themselves are tabulated in the code for reference.
The Time-Dependent Factor
The long-term multiplier is built from a time-dependent factor that increases with the duration of the sustained load, rising in steps from three months through six and twelve months to five years or more, combined with a reduction reflecting the compression reinforcement ratio. The note also records that the industry commentary on the earlier code edition recommends a somewhat higher time-dependent factor for two-way slabs under sustained load beyond five years than the general value. Selecting the appropriate factor is therefore part of the engineer's input rather than automatic.
Choice of Sustained Load Combination
Before checking, the engineer must decide whether the sustained load is the full dead plus live load or dead plus half the live load, according to how the space is used, and set that choice in the slab load combination. By default the meshed slab module reviews the combinations composed only of dead and of dead plus full live load that are registered as serviceability combinations. The distinction matters because the long-term deflection is proportional to whichever sustained load is chosen.
Cracked Section Analysis Algorithm
A linear elastic analysis is run first to obtain the effective moment of inertia from the code expressions, then the analysis is repeated with that effective stiffness under the chosen slab load combination. The effective moment of inertia before and after each pass is compared and the iteration continues until the convergence condition set in the cracked section analysis control is satisfied, at which point the analysis terminates. The immediate deflection for the sustained load is taken from the converged cracked analysis and then multiplied by the time-dependent and long-term factors to give the additional deflection.
Load Combination Types in Meshed Slab Design
Three types of slab load combination serve different purposes: strength combinations for the slab strength check, serviceability combinations for the uncracked deflection check, and deflection combinations for deflection based on the cracked section. Before the long-term check, the linear analysis must be complete, the serviceability type must be set on the concrete tab of the load combination dialog, and the relevant gravity load combinations must be confirmed in the meshed design slab load combination list.
Entering Slab Reinforcement
Because cracking depends on the reinforcement present, bars must be assigned to the slab mesh elements before the long-term deflection can be computed. Two routes are available: running the automatic slab flexural design and then pressing the update rebar command to write the designed reinforcement into each element, where it can be inspected in the work tree, or entering the reinforcement directly into each element with the slab rebars for checking function. Without reinforcement data the cracked analysis cannot proceed.
Running the Analysis and Reading Results
The number of iterations per load case and the convergence tolerance are set in the cracked section analysis control, and the note warns that too few iterations end the run in a non-converged state where the crack-induced deflection is understated, so a generous iteration count is recommended. The cracked section analysis is then performed from the meshed design menu. Selecting an element in the model view and requesting the design result outputs the check for that element by domain, and with no element selected the result is reported for each domain.
Total Deflection Including the Immediate Component
The second tutorial forms the total deflection as the long-term deflection under sustained load plus the immediate deflection, by adding the sustained load and immediate deflection cases directly as serviceability combinations, with the sustained load taken as dead plus half the live load in that example. The deflection check automatically identifies the combinations made up only of dead and live load and carries them into the crack analysis. The workflow otherwise repeats the reinforcement entry, control setting and analysis steps of the first tutorial.
Long-term slab deflection in midas Gen is obtained by iterating a cracked-section finite element analysis until the effective moment of inertia converges, then scaling the resulting immediate deflection under the chosen sustained load by the code time-dependent and reinforcement-dependent factors. The engineer must set the sustained load combination to suit the occupancy, assign reinforcement to the slab elements, and allow enough iterations for convergence, after which the long-term and total deflections are reported by element or by domain.