[EN_GEN] Modeling a Structure with Underground Stories

PDF
·
12ページ
·
1.1MB
·
English
·
2025.03.11 更新
概要

This technical note explains how basement (underground) stories should be handled when a building is modeled for lateral load analysis in midas Gen. Underground stories are generally not subject to lateral loads, yet they must be represented when they transfer the weight of the superstructure or act as part of the lateral load resisting system. The note presents four interacting issues and then demonstrates the corresponding midas Gen settings on a worked model.

主要内容

01

Defining the Ground Level for Lateral Load Generation

Using Model > Building > Control Data, the Use Ground Level option and a ground level elevation are defined so that wind and static seismic loads are generated only above grade. Without this definition, the program distributes lateral pressure onto basement stories as well. Story-wise wind load tables let the user confirm where load application actually begins.

02

Wind Load at Supported Levels

Lateral load that would be applied at the base cannot be resisted by the model because support conditions restrain those nodes, so midas Gen automatically excludes it and reports this in the Command Message window. Story loads are computed from the pressure acting over half the height above and below each diaphragm. Reviewing the Wind Load Profile dialog verifies the resulting distribution.

03

Mass Below Ground Level in Eigenvalue Analysis

A separate Control Data option controls whether the mass of underground stories participates in eigenvalue analysis. Including or excluding this mass changes modal participation masses substantially, which in turn affects response spectrum results. The choice must therefore be made deliberately rather than left at a default.

04

Lateral Restraint of the Underground Structure

The degree of lateral restraint provided to basement levels depends on soil properties, the number of underground levels and the stiffness of basement walls and floor diaphragms. In midas Gen this is best modeled with point spring supports at each underground story, which avoids interference with the rigid links generated by story diaphragms. Comparative results show that lateral displacement of the building changes greatly depending on whether these supports exist.

05

Choosing the Spring Stiffness

The lateral stiffness assigned to underground supports should reflect soil frictional resistance, active pressure on basement walls and the stiffness of the walls themselves. Where a fully restrained assumption is intended, a sufficiently large stiffness value is entered for the translational and rotational spring components at each underground story. The note gives the practical procedure for selecting nodes story by story and applying the springs.

06

Checking Base Shear from Response Spectrum Analysis

When spring supports are present, the base shear from a response spectrum load case is reported in a With Spring column, and can be cross-checked by summing horizontal reactions in the Results > Result Tables > Reaction output. This verification confirms that the intended proportion of seismic force reaches the foundation rather than the basement springs. It is an essential check whenever underground restraint is modeled.

07

Worked Modeling Sequence

The final section applies all of the above to a tutorial steel structure: turning on Use Ground Level with an elevation of zero, switching off mass below ground level for eigenvalue analysis, activating the basement stories to place point spring supports, running the analysis and reviewing base shear. The sequence of menu commands and display settings is listed so the user can reproduce it. This ties the conceptual discussion to concrete program operations.

まとめ

Correct treatment of basement stories requires three deliberate decisions in midas Gen: where the ground level sits for lateral load generation, whether underground mass contributes to eigenvalue analysis, and how underground lateral restraint is represented. Point spring supports at each underground story are the recommended way to model that restraint, and base shear should always be verified from the reaction output afterwards.

関連資料

同じカテゴリー・トピックから厳選した資料です。

STRUCTURE · MIDAS NOTE[KR_ADS] midas ADS를 이용한 구조물의 지하층 모델링 기법
STRUCTURE · SEMINAR[KR_2021.04] 실무자를 위한 지하구조물(KDS 41 17 00) 내진설계(김달기)
STRUCTURE · MIDAS NOTE[EN_GEN] ACI 318-19 Updates for ULS Design of Reinforcement Concrete
STRUCTURE · MIDAS NOTE[EN_GEN] Analysis and Design of Structures using the Nodal Body Force Function