[EN_GEN] Post Tension Design_04 Design Tip & Example

PDF
·
13ページ
·
2.7MB
·
English
·
2025.03.11 更新
概要

The fourth part of the midas Gen post-tension series gathers practical design guidance, the rules for additional (extra) reinforcement, and a worked example on an equivalent frame. It identifies the three quantities the designer actually chooses in a post-tensioned member, gives ranges for each, and then sets out minimum reinforcement areas and lengths for unbonded systems. The example applies the guidance to an unbonded slab with defined superimposed dead, dead and live loads.

主要内容

01

The Three Design Variables

Post-tension member design reduces to three choices: the average linear compressive stress to be introduced into the section, the magnitude of the balanced load, and the arrangement and shape of the tendons. Fixing these three effectively fixes the design, so the guidance in this part is organised around them. Everything else follows as a verification.

02

Selecting the Average Linear Compressive Stress

Tendon spacing is set so that the average linear compressive stress on the section meets a code minimum, with a somewhat higher range recommended for roof slabs where crack control matters most. Upper practical limits are also suggested, differing between slabs and beams, above which further precompression is uneconomical. These bounds convert a crack-control requirement into a tendon spacing decision.

03

Selecting the Balanced Load

The balanced load is the vertical load that the tendon profile applies to the structure at the positions where the tendons are placed. It is computed by averaging the upward force over the whole span and expressing it as a proportion of self-weight, with economical ranges given separately for slabs and for beams. Choosing this ratio is how the designer decides how much of gravity load the prestress will offset.

04

Tendon Arrangement Patterns

Layouts are shown for continuous beam-and-slab construction, slab bands and two-way slabs, including the uniform and banded distributions used in two-way work. The arrangement controls where the balanced load is actually delivered and which strips of the slab rely on it. It also interacts directly with the additional reinforcement rules that follow.

05

Role of Extra Reinforcement

Additional bonded reinforcement serves two purposes: controlling cracks under service loading and providing adequate ductility at ultimate load. In an unbonded system this reinforcement is essential because the tendon cannot develop local bond. The note therefore treats extra rebar as an integral part of the design rather than as detailing.

06

Minimum Reinforcement in Two-Way and One-Way Slabs

For two-way slabs the minimum area in negative moment regions is proportional to the tributary area of the equivalent beam, evaluated for both the column strip and the slab band configurations, while positive moment regions require reinforcement wherever the concrete tensile stress exceeds a stated fraction of the compressive strength, sized from the resulting tensile force. For one-way slabs a minimum proportion of a defined moment area is placed at the top over columns and at the bottom at midspan. Minimum lengths are also prescribed as fractions of the net span, measured into the span for positive regions and from the column face for negative regions.

07

Shrinkage, Temperature and When Extra Rebar Is Not Needed

Where the average compressive stress introduced over the whole section is low, a combined criterion on precompression and reinforcement area must be satisfied to cover shrinkage and temperature effects. In bonded systems no extra reinforcement is required when the member already satisfies the service load requirements of the design code and the strength requirements. This gives a clear exemption test rather than a blanket rule.

08

Equivalent Frame Design Example

The example takes an unbonded system with stated superimposed dead, dead and live loads, forms the service and factored load combinations, and defines two column sizes and a storey height. The slab is analysed as an equivalent frame and the design tips and reinforcement rules are applied to it. This demonstrates the whole part in a single continuous calculation.

まとめ

Part four converts the code procedure into design decisions by giving working ranges for average precompression, balanced load ratio and tendon layout, and by specifying the minimum additional reinforcement that unbonded systems require for crack control and ductility. The equivalent frame example ties these choices together and shows the exemption conditions under which extra reinforcement can be omitted.

関連資料

同じカテゴリー・トピックから厳選した資料です。

STRUCTURE · MIDAS NOTE[EN_GEN] ACI 318-19 Updates for ULS Design of Reinforcement Concrete
STRUCTURE · MIDAS NOTE[EN_GEN] Analysis and Design of Structures using the Nodal Body Force Function
STRUCTURE · MIDAS NOTE[EN_GEN] Analysis and design method of structures using tension-only elements
STRUCTURE · MIDAS NOTE[EN_GEN] Calculation of stiffness center