This sixth instalment of the high-rise design series addresses progressive collapse, in which local damage from an abnormal load such as impact or explosion propagates into collapse of the whole structure. It explains the load-carrying mechanisms a frame passes through after losing a column, the detailing that keeps those mechanisms available in steel and concrete construction, and the analysis methods and acceptance criteria set out in the American guidance documents.
主要内容
What Progressive Collapse Is
Progressive collapse is defined as the phenomenon in which local structural damage caused by an abnormal load leads to collapse of the entire structure, so the engineer must design against it during the structural design stage. The presentation cites the collapse of the World Trade Center towers and the partial collapse of the Murrah Building in Oklahoma City. The mechanism is traced as damage to a primary member, loss of that member, failure of the remaining members, and the dropping mass extending the failure downward.
Load Paths After Column Loss
When a column is removed, the beams above it must span twice their original length and develop a large moment. The frame first mobilises compression arch action in the beams, then passes through a transition phase, and finally reaches a stable condition by catenary action in which the beams carry the load in pure tension. Because the catenary state is the one that remains stable at large deflection, the design objective is to ensure catenary action can be developed and maintained.
Detailing for Catenary Action in Steel and Concrete
In steel construction the connections must be reinforced so that they can transmit the tension demanded by catenary action rather than failing once the moment capacity is exhausted. In reinforced concrete the equivalent measures are continuous bottom reinforcement through the joint, additional reinforcement specifically provided for catenary action, and shear reinforcement detailing following published research, with test specimens detailed using partial hinges cited as an alternative approach. In both materials the joint, not the member, is the critical element.
Alternative Path Method
The alternative path method assumes one structural element is destroyed by the abnormal load and then checks whether the remaining elements can redistribute the load, verifying their limit states. Four analysis routes are available, linear or nonlinear, each in static or dynamic form. Linear analyses are assessed by a demand capacity ratio, while nonlinear analyses are assessed against allowable ductility and element rotation, the latter being the measure appropriate to the large deflections of catenary action.
Demand Capacity Ratio Criteria
For the static linear route the demand is the member force and the capacity the member strength, with the strength reduction factor applied according to the importance of the structure, and the resulting ratio is compared with tabulated limits. The American General Services Administration guidance permits higher ratios than the Department of Defense guidance for highly important buildings, and in both cases irregular structures are held to a stricter limit than regular ones; for steel the limit depends on the width-to-thickness ratio of the section. The service load is amplified, doubled in the linear static route, to account for the dynamic nature of the sudden member loss.
Direct Design Method Workflow
Following the General Services Administration guidance, the direct design procedure enters the reinforcement data into the members, removes the target column, computes the member forces by static linear analysis, evaluates the demand capacity ratio and compares it with the allowable value, revising the member design where it fails. Where the ratio far exceeds the limit, a pin is introduced at that element end to represent the loss of moment capacity and the analysis is repeated. A fifteen-story example runs three successive evaluations, each converting the most overstressed elements to pins, and reaches a state where all the relevant ends are pinned, which is identified as progressive collapse.
Preventing progressive collapse means ensuring that a frame which loses a column can pass from compression arch action through to stable catenary action, which depends primarily on joint detailing, continuous bottom reinforcement and connection tension capacity. Verification follows the alternative path method, either by comparing a demand capacity ratio against the limits in the American guidance for the linear routes, or by checking ductility and element rotation for the nonlinear routes, with the iterative pin-release procedure showing whether the structure stabilises or collapses.