This user's guide answers eight frequently asked questions about linking midas Design+ to midas Gen so that geometry and member forces can be imported for detailed design. It explains how the link is established, what data is transferred under which conditions, and the limitations that apply to particular member types. Several answers explain apparent inconsistencies, such as forces changing after a design run or wall results differing between the two programs.

主要内容

01

Establishing the Link

The link is made through the midas Link menu, where the Gen file is selected from a list and connected, after which both programs display a confirmation message. Once linked, the name field for adding a new member changes to Member for the beam, column, wall and connection modules and to Node for the footing and base plate modules, and the user selects a member or node in Gen and imports it, or types its number directly. The design code specified in both programs must be identical, and the supported member types are reinforced concrete beams, columns, shear walls, footings and batch walls plus steel beams and columns, base plates and bolt connections.

02

When Member Forces Are Not Imported

If design or checking has not been performed in Gen there are no design results, so only the member name, material properties, section shape and section size are imported and neither member forces nor reinforcement data come across. This is deliberate: it accounts for design parameters such as the member redistribution factor that Design+ does not provide, and using identical design member forces is what allows the two programs to reach the same result. Once design has been performed, the member forces and the reinforcement computed during design are exported, and if code checking was performed with assigned reinforcement then the forces come with that assigned reinforcement.

03

Footing, Base Plate and Connection Forces

For footings, base plates and bolt connections the design member forces are obtained by running an analysis rather than a design. This distinguishes them from beams, columns and walls, where a design or check run in Gen is the prerequisite. The guide flags this as a separate rule for those three module types.

04

Designing the Most Critical Member by Section

The link option menu offers a link type of link by section, which imports the most critical design result among all members sharing identical section properties, as opposed to link by member which imports the forces of the selected member only. For reinforced concrete beams the critical case is the largest absolute member force from the Gen analysis. For columns, shear walls and steel beams and columns, the additional choices are the load combination giving maximum or minimum axial force, moment and shear across all components, or the maximum or minimum combination for a single selected force component.

05

Footing and Connection Envelope Options

For reinforced concrete footings, the options extend to importing all load combinations from Gen, the maximum or minimum combinations across all components or for a selected component, or an envelope taking the largest value of each force component separately. For steel bolt connections the envelope option is likewise available. These choices determine how conservative the imported design forces are.

06

Base Plate Link Limitations

The base plate link is not supported in several situations: when the reinforced concrete column, beam or wall below is smaller than the steel section above; when the steel member is neither perpendicular nor horizontal relative to the member below; when the lower member is not reinforced concrete; when a target member at the bottom of the structure has no support beneath it; and when a brace member is present. Each case is illustrated. These are geometric and material preconditions rather than settings the user can change.

07

Why Base Plate Forces Change After Design

Importing a node for base plate design brings in six load combinations, containing the maximum and minimum of axial force and of the major and minor moments respectively. Before the design run the force field shows the first of those, the one with maximum axial force. After running the design or check, the program identifies the most critical combination and displays its forces instead, but internally all six combinations are always verified regardless of which one is shown.

08

Bolt Connection Member Assignment and Wall Design Differences

Member assignment does not have to be defined in Gen for bolt connection design, because the program finds continuous beams automatically, first from any member assignment information that does exist, then by identifying girders from the positions of columns and walls, then by identifying sub-beams divided by other sub-beams with the lower element ID taking priority. For walls, the design method is set in Gen through the end rebar design method under the shear wall design criteria, while in Design+ there is a use design method of Gen option; if that option is left unchecked, Design+ applies its own second wall design method, which is why the two programs can report different wall results.

まとめ

The Gen link transfers geometry unconditionally but transfers member forces and reinforcement only once design or checking has been run in Gen, which is what keeps the two programs' results consistent, while footings, base plates and connections need only an analysis. The remaining questions resolve to explicit options: link by section versus by member with several critical-case definitions, the six-combination base plate import whose displayed force changes to the governing case after design, automatic member assignment for bolt connections, and the use design method of Gen option that reconciles wall design results.