[EN_DESIGN+] Preference in Design+

PDF
·
9ページ
·
1.3MB
·
English
·
2025.03.11 更新
概要

This user's guide answers nine frequently asked questions about the preference and option settings that govern how midas Design+ designs members. Each answer gives the menu path and the specific option to enable, and notes what the program does by default. The questions cover section optimisation limits, reinforcement and steel ratio caps, reusable rebar spacing and section lists, base plate modelling, default input data and the development length calculator.

主要内容

01

Letting Design Update the Section Size

By default Design+ changes only the reinforcement data during design and leaves the section size alone, which is why a section appears not to be updated after design. Enabling the change section by design option in the design option dialog lets the program find an optimised section size and write it back. This single option is the prerequisite for most of the size-limit settings that follow.

02

Maximum Member Dimensions

With change section by design enabled, a maximum height can be specified for reinforced concrete beams in the design option dialog. The same mechanism provides a maximum dimension for other member types including reinforced concrete columns, walls, footings, buttresses, stairs, corbels and brackets, and steel base plates. These caps bound the optimisation so it does not return impractical sections.

03

Maximum Reinforcement and Steel Ratios

For a reinforced concrete column, a maximum reinforcement ratio can be entered in the design option dialog once change section by design is enabled. For a concrete filled tube column, a maximum steel ratio option is provided under the composite section settings. Both act as limits on what the automatic design is allowed to select.

04

Registering Frequently Used Rebar Spacing

The rebar option dialog, reachable from the main menu or from the design option branch of the tree menu, holds a list of preferred bar spacings. Desired spacings are checked and added for moment design and for shear design separately, and values can also be typed directly into the moment or shear tab table. The design then chooses from the registered spacings rather than arbitrary values.

05

Restricting the Steel Section Database

The steel option dialog holds the list of steel beam and column sections that the design is allowed to use. Sections are chosen by shape and name from the database field and moved into the beam or column list, and can be removed again from that list. This keeps steel design within the sections that are actually available to the project.

06

Base Plate Modelling Options

Base plate design uses a rigid plate assumption by default, but the steel option dialog offers a soft plate option that performs a finite element analysis of the plate instead. The choice is made on the design tab of that dialog. The guide notes that the soft plate option does not support the design function, only the analysis.

07

Default Design Data for New Members

Initial values for newly added members can be defined by the user through the tools menu. Set default data for all modules applies the specified design input values to newly added members of a chosen member type across the whole program, while the current-module version applies the values entered in the module being worked on and has a keyboard shortcut. A reset command returns the defaults to the values recommended by the program.

08

Development and Splice Length Calculator

A dedicated calculator computes rebar development and splice lengths according to the concrete design standards. It is launched from the tools menu and the required case is then selected within it. Six cases are supported: development length in tension by both a simple and a detailed method, development length in compression, development length for a hooked bar in tension, and splice length in tension and in compression.

まとめ

Most of the questions resolve to the change section by design option, which is off by default and gates whether Design+ optimises section sizes at all, together with the maximum dimension, reinforcement ratio and steel ratio limits that bound that optimisation. The remaining preferences let the engineer constrain the design to available bar spacings and steel sections, choose between rigid and finite element base plate behaviour, define default input for new members, and compute development and splice lengths through a built-in calculator.