The second part of the midas Gen time-history series is a complete tutorial on a simple reinforced concrete building. It starts from an elastically designed model with defined reinforcement, sets up the global control and time-history load case, defines and assigns hinge properties, and then reviews the response through result graphs, yielding status and story drift. It closes by showing how the time-history results are carried into member design.
핵심 내용
Model Description
The example is a five-story reinforced concrete frame and wall system of moderate height, with rectangular columns, beams and thin walls of stated dimensions, designed to ACI 318M-14. Gravity loading consists of the frame self-weight plus a superimposed dead load and a live load. Seismic loading and an eigenvalue analysis are also defined as part of the base model.
Prerequisite: Elastic Design and Reinforcement Input
Before inelastic analysis, reinforcement satisfying elastic design under the code must be entered for beams, columns and walls. The design must actually be run, because the design strength obtained for each member is what the hinge properties are built from. Skipping this step leaves the hinges without a defensible capacity.
Global Control and Initial Load
The gravity loads acting during the earthquake are assembled in Global Control by selecting each load case and giving it a scale factor. The recommendation is to take the full dead load and a partial fraction of the live load. This combination becomes the initial load state on which the dynamic response is superimposed.
Setting the Time-History Load Case
The load case is named, the analysis type is set (nonlinear direct integration for the general case), and the end time and time increment are entered, with the increment chosen as a small fraction of the fundamental period. The initial load defined in Global Control is activated, and the damping method is selected, typically mass and stiffness proportional, using the cycles of the first and second modes in the direction of interest. These settings determine both accuracy and run time.
Defining Hinge Properties
A hinge is named and assigned an element type and material type, and its flexural behavior is set as moment-rotation, or as moment-curvature where a Eurocode basis is used. Axial-moment interaction is set to none for beams and to P-M or P-M-M for columns and walls, and the inelastic components are checked accordingly, with axial and major-axis bending for beams and the fuller set for columns and walls. A skeleton curve is then chosen, commonly kinematic hardening.
Assigning and Editing Hinges
Hinges are applied by selecting the element type, the hinge property and the target members, repeating until every member is covered, and then running the analysis. The work tree allows user editing of the assigned properties: for the force components the hinge curve, yield strength, yield displacement and acceptance criteria can be edited, and for the moment components the yield strength and P-M interaction curve as well. This lets the engineer override program defaults where test or code data are available.
Checking Yielding Status
With the time-history load case and the step corresponding to peak displacement selected, the status of yielding is displayed for the chosen component and reviewed member by member in the model window. In the sample model some walls reach a second yield level, indicating that reinforcement of those elements is required. This is the direct diagnostic output of the inelastic analysis.
Story Drift and Performance Levels
Story results must be enabled before the analysis is run. The drift check is then set up by selecting the time-history load case, entering factors of unity as appropriate to inelastic analysis, specifying the allowable ratio and adding the vertical load case. Allowable rotation and short-term story drift limits are tabulated against the performance levels from fully operational through operational and life safety to near collapse, and the computed drift is compared against the level targeted for the building.
The tutorial demonstrates a full inelastic time-history assessment of a low-rise reinforced concrete building in midas Gen, from elastic design and reinforcement input through hinge definition and assignment to response graphs, yielding status and drift verification against performance levels. Its practical outcome is a diagnosis of which elements yield beyond the acceptable level, and a route for feeding the inelastic demand back into member design.