[EN_GEN] Pushover & TH_S05 TH Tutorial for simple building with seismic control device

PDF
·
12페이지
·
1.5MB
·
English
·
2025.03.11 업데이트
요약

The fifth part of the midas Gen time-history series is a step-by-step tutorial on modeling a seismic control device in a simple building and evaluating its effect. A five-story steel frame designed to AISC-LRFD receives viscoelastic dampers, which are defined as device properties, wrapped in a general link and installed between nodes. The tutorial then sets the initial load, the time-history load case and the earthquake ground motion, and reviews the damper energy and hysteresis output.

핵심 내용

01

Model Description

The example building is a five-story steel moment frame of moderate height with H-section columns and beams and no walls, designed to AISC-LRFD. Gravity loading comprises self-weight with a superimposed dead load and a live load. The absence of shear walls means the dampers become the principal additional source of energy dissipation.

02

Damper Layout Alternatives

Two installation configurations are shown for placing the viscoelastic dampers within the frame bays. The chosen arrangement determines the relative displacement the device experiences and therefore how much energy it can dissipate. Comparing layouts is presented as part of the modeling decision rather than an afterthought.

03

Step 1: Defining Damper Properties

The damper is named, its target material type selected, and its physical dimensions entered, with a distinct option for indoor installation. These inputs generate the device's mechanical characteristics from the manufacturer's material model. This is the level at which the physical product enters the model.

04

Step 2: Defining a General Link for the Damper

A general link is created, the previously defined damper is attached to it, and linear properties are entered for the link. The guidance is to base those linear properties on an eigenvalue analysis so that the link stiffness matches the damper stiffness. Keeping the two consistent prevents the link from artificially adding or removing stiffness.

05

Step 4: Setting Global Control and Initial Load

The method for applying the initial load is selected and the initial loads themselves are entered, normally the gravity load combination. This state establishes the condition on which the dynamic response is superimposed. The same initial load is later referenced from the time-history load case.

06

Step 5: Setting the Time-History Load Case

The load case is named, nonlinear direct integration is chosen as the analysis type, and an end time and time increment are set, the increment taken as a small fraction of the natural period. The initial load option is enabled and the damping method selected, typically mass and stiffness proportional using the first and second mode cycles in the direction of interest. These settings mirror those of the earlier inelastic tutorial.

07

Step 6: Defining the Earthquake Ground Motion

A time function is created either by selecting a recorded historic earthquake from the program's library or by pasting acceleration values from an external tool. The function is then assigned to the load case as ground acceleration in each direction and added before the analysis is performed. Using more than one record is what makes the maximum and average result tables meaningful.

08

Reviewing Damper Performance

Results include time-history graphs of the response, an energy graph that separates the damping energy dissipated by the viscoelastic dampers, and plots of the hysteresis behavior of each device. The energy output quantifies how much of the input the dampers absorbed, and the hysteresis loops show whether they are working over their intended deformation range. Together these confirm whether the control device is actually effective.

정리

The tutorial establishes the modeling chain for a passive control device in midas Gen: define the damper as a seismic device property, wrap it in a general link whose linear stiffness matches the device, install it between nodes, and run a nonlinear direct integration analysis with gravity as the initial load and a recorded ground motion. Damper effectiveness is then judged from the dissipated energy graph and the hysteresis loops of the installed devices.

관련 자료

같은 카테고리와 주제에서 선별한 자료입니다.

STRUCTURE · MIDAS NOTE[EN_GEN] Pushover & TH_S06 Introduce Seismic control devices in midasGen
STRUCTURE · MIDAS NOTE[EN_GEN] Pushover & TH_S02 TH Tutorial for simple building with inelastic properties
STRUCTURE · MIDAS NOTE[ES_GEN] Modeling of non-linear boundary elements
CIVIL · TUTORIAL[EN_CIVIL] Nonlinear time history analysis of a bridge with viscous dampers