[EN_GEN] Pushover analysis in midas Gen_S01 Introduction of inelastic static analysis

PDF
·
10 pages
·
2.2MB
·
English
·
Updated 2025.03.12
Summary

This is the first part of a five-part midas Gen series on pushover analysis. It places inelastic static analysis within the four seismic design methods the program supports, explains the limits of the traditional force-based approach, and introduces the concepts of performance-based seismic design, capacity design and performance objectives. It also lists the guideline documents that established the modern framework.

Key Topics

01

Four Seismic Analysis Types in midas Gen

The program supports equivalent seismic load analysis (static and elastic), modal response spectrum analysis (dynamic and elastic), pushover analysis (static and inelastic) and inelastic time-history analysis (dynamic and inelastic). Arranging them on the static-dynamic and elastic-inelastic axes shows exactly what each adds. Pushover analysis occupies the position of an inelastic method that remains computationally simple.

02

How Inelastic Analysis Evaluates Seismic Response

Inelastic static analysis estimates the resistance capacity of the structure, and the required strength is then determined by comparing that capacity with the required performance. The evaluation can use the seismic response of an equivalent single degree of freedom system, working with the converted displacement and resistance force, or the response of the full multi degree of freedom system, using its representative response. The required seismic level is evaluated through an inelastic response spectrum.

03

Capacity-Based Performance Evaluation Methods

Response calculation and performance evaluation are carried out on the basis of the capacity design method. The available procedures include the displacement coefficient method, the capacity spectrum method and direct displacement based design. These are the alternatives developed in detail in the later parts of the series.

04

Limits of the Traditional Approach

In an actual earthquake it is impossible to predict the damage pattern of a building from a conventional force-based design. Inelastic analysis is presented as the means to predict both building performance and which members will fail. This shift in objective, from checking forces to predicting damage, motivates the whole series.

05

Performance-Based Seismic Design

Performance-based seismic design is described as a next-generation design philosophy encompassing all the analysis and design procedures needed for a structure to secure predictable seismic performance and achieve a specified performance objective. Its defining feature is that the design satisfies a stated performance objective in the event of an earthquake rather than merely a code force level. The note lays out the procedure that this philosophy implies.

06

Capacity Design

Capacity design is the process of deciding which elements of the structural system are permitted to yield, becoming the ductile components, and which must remain elastic as brittle components. This deliberate allocation of yielding is what makes the failure mechanism predictable. It is the design counterpart to the analytical prediction that pushover analysis provides.

07

Global Framework and Its Benefits

The PEER global framework for performance-based seismic design is presented as the reference structure for the whole process. By quantitatively evaluating damage as a function of earthquake magnitude, it secures reliability of safety and minimises the damage and the repair and strengthening costs incurred. Accurate performance evaluation also allows the value of a building, including insurance cost, to be assessed properly.

08

Performance Objectives and Guideline Documents

A performance objective pairs a damage level with a magnitude of seismic load, and is set according to both the earthquake return period and the use of the building. The performance point is where the evaluated response meets that objective. The guideline documents cited as the basis for this framework include ATC-40, FEMA-273, the SEAOC Blue Book, ATC-44, FEMA-356 and ATC-55.

Conclusion

Part one establishes why inelastic static analysis is needed: conventional force-based design cannot predict which members will be damaged, whereas pushover analysis estimates the structure's capacity so that it can be compared against a stated performance objective. It positions pushover analysis among the four analysis types in midas Gen and introduces the performance-based and capacity design concepts, together with the ATC and FEMA guidelines, that the remaining parts build on.

Related Resources

Hand-picked materials in the same category and topic to deepen your workflow.

STRUCTURE · PRODUCT MANUAL[KR_Nonlinear Analysis] 01_Pushover Analysis
STRUCTURE · MIDAS NOTE[EN_GEN] Pushover analysis in midas Gen_S02 Methods for inelastic static analysis
CIVIL · MIDAS NOTE[KR_CIVIL] 성능기반 내진설계의 이해
STRUCTURE · MIDAS NOTE[KR_ADS] 비선형 지진해석을 이용한 건축구조물의 내진성능 평가