[EN_GEN] Structural Design Guide for Prestressed Slabs

PDF
·
48 pages
·
7.9MB
·
English
·
Updated 2025.03.11
Summary

This guide, the second volume in the Structure Insight series, is a practical handbook for the structural design of prestressed and post-tensioned concrete slabs. It moves from the basic concept of post-tensioning through the full design flow of tendon selection, stress checking, loss evaluation and strength verification, and then into practical detailing tips and a worked building example. The final chapter is a step-by-step tutorial showing how a post-tensioned beam is modelled and loaded in midas Gen.

Key Topics

01

What Post-Tensioning Is and Where It Is Used

Post-tensioning places prestressing cables inside plastic ducts or sleeves in the formwork before the concrete is cast, then tensions and anchors them once the concrete has gained strength but before service loads arrive. It differs from pre-tensioning, where the steel is stressed before the concrete is poured, but both are forms of prestressing because the steel carries stress ahead of the service load. The guide lists the practical benefits: reduced or eliminated shrinkage cracking and therefore fewer joints, tighter closure of any cracks that do form, thinner slabs and members, the ability to build on expansive or soft soils, and longer spans in elevated floors and beams.

02

Bonded versus Unbonded Systems

Bonded post-tensioning is directed at large structural elements such as beams and transfer girders, where it delivers longer spans, higher load-carrying capacity and reduced deflection. Unbonded post-tensioning is the usual choice in new construction for elevated slabs, slabs on grade, beams, transfer girders, joists, shear walls and mat foundations. The unbonded monostrand is light and flexible enough to be installed quickly, which is what makes it the economical option for slab work.

03

Prestressing Steel Properties and Allowable Stress

The guide tabulates the strand properties needed for design, including area, specified tensile strength, specified yield strength and effective prestress, for the common strand diameters. Allowable tendon stress is limited differently immediately after prestressing than after anchoring, with the jacking limit taken as the lesser of two fractions of the yield and ultimate strengths. From these limits the maximum prestress force at jacking and the effective prestress force after losses are derived for each strand size.

04

Three Design Stages and Their Check Items

Design is organised around a transfer stage, a service stage and an ultimate stage, each with its own prestress force, concrete strength and loading. At transfer the maximum prestress force acts on concrete that has only reached its strength at the time of stressing, under self weight alone, so the checks are tensile cracking, concrete crushing and anchorage zone failure. At the service stage the effective prestress force acts with full unfactored design loads and the checks are deflection and crack width, while at the ultimate stage factored loads are applied and flexural failure is the governing check.

05

Tendon Force, Profile and Stress Checking

The design flow begins with choosing the tendon force and profile, with parabolic profiles arranged to balance the applied load being the standard approach. Final and initial stresses are then checked against allowable concrete stresses in compression and tension and against the allowable tendon stress. The guide illustrates the calculation on a simple beam and shows how the stress distribution over the section changes with the tendon arrangement, which is the key to understanding why profile choice governs the result.

06

Prestress Losses

Losses are separated into those occurring at and immediately after jacking and those developing over time. The immediate group comprises anchorage seating, friction along the duct and elastic shortening of the concrete. The time-dependent group comprises concrete creep, concrete shrinkage and relaxation of the strand, and together these define the difference between the initial and the effective prestress force used in the service stage checks.

07

Primary and Secondary Moments, Detailing and Worked Example

In a continuous member the primary moment arises from the eccentricity between the tendon and the section centroid, while restraint at intermediate supports generates an additional secondary or parasitic moment that must be combined correctly to obtain the design moment. A practical chapter then covers the assumptions normally made in post-tension design, the rules for arranging tendons in a slab, and the extra bonded reinforcement required, which differs between unbonded and bonded systems. A complete building example runs through the service stage check, the secondary and design moments, the nominal flexural strength and the punching shear check at the slab-column connection.

08

Modelling a Post-Tensioned Beam in midas Gen

The tutorial chapter shows the modelling sequence: defining the tendon material, setting the post-tensioning tendon property with duct and friction data, and defining the tendon profile geometry along the member. Prestressing loads are then applied to the tendons as a separate load type. Because prestress is introduced progressively, the loads are activated within a construction stage so that the transfer and service conditions are reproduced in the correct order.

Conclusion

The guide presents post-tensioned slab design as a disciplined sequence: select a tendon force and profile, verify stresses at transfer and in service, quantify both immediate and long-term prestress losses, and then confirm flexural and punching shear strength at the ultimate stage. Special attention is required for the secondary moments that arise in continuous members and for the extra reinforcement rules that differ between bonded and unbonded systems. The closing tutorial connects the theory to practice by showing how tendon properties, profiles and prestressing loads are entered and staged in midas Gen.

Related Resources

Hand-picked materials in the same category and topic to deepen your workflow.

STRUCTURE · MIDAS NOTE[EN_GEN] Post Tension Design_01 Intro for P.T System
STRUCTURE · MIDAS NOTE[KR_GEN] Prestressed beam & slab 의 구조해석 및 설계기술
STRUCTURE · MIDAS NOTE[EN_GEN] Post Tension Design as per ACI318M
STRUCTURE · MIDAS NOTE[EN_GEN] Post Tension Design_02 Design for PT system